Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

IB514020EN
Installation Instructions - VWM Vision Wall Medium
Instructions d'installation - VWM Vision Wall moyen
Instrucciones de instalación - VWM Vision Wall Medium
WARNING
Make certain power is OFF before starting installation
or attempting any maintenance.
WARNING
Risk of fire/electric shock. If not qualified, consult an
electrician.
WARNING
Risk of Electric Shock – Disconnect power at fuse or
circuit breaker before installing or servicing.
WARNING
Risk of Personal Injury – Fixture may become damaged
and/or unstable if not installed properly.
Do not mount luminaire within 6" of a combustible
surface.
Do not handle luminaire by the glass. Do not touch
LEDs.
IMPORTANT: Read carefully before installing fixture. Retain for future reference.
GENERAL: Upon receipt of the fixture, thoroughly inspect for any freight damage which should be brought to the
attention of the delivery carrier. Compare the catalog description listed on the packing slip with the fixture label on the
housing to assure you have received the correct material.
SAFETY: This fixture must be wired in accordance with the National Electrical Code and applicable local codes and
ordinances. Proper grounding is required to insure personal safety. Carefully observe grounding procedure under
installation section.
APPLICATIONS: This lighting fixture is designed for outdoor lighting services, and should not be used in area of limited
ventilation or inside high ambient temperature enclosures. It must be stored in a dry location prior to installation. Do
not expose lighting fixture to rain, dust or other environmental conditions prior to installation and insertion of photo
control or shorting cap (if so equipped). Do not install the fixture near combustible materials or locate next to airflow
blocking surfaces within 6 inches. Best results will be obtained if installed and maintained according to the following
recommendations.
WARNING
Risk of Burn – Disconnect power and allow fixture to
cool before servicing.
N
ote:
These instructions do not claim to cover all
details or variations in the equipment, procedure,
or process described, nor to provide directions
for meeting every possible contingency during
installation, operation or maintenance. When
additional information is desired to satisfy a
problem not covered sufficiently for user's purpose,
please contact your nearest representative.
N
ote:
This lighting fixture has been shipped complete
with one of several mounting options. Please follow
the installation instructions specific to the catalog
part that you ordered.
N
ote:
Care must be taken not to set lighting fixture down
on optical lenses or lift the fixture in the lens area.
Specifications and dimensions subject to change
N
ote:
without notice.
Brand Logo
reversed out of
black
INS #
INS #

Publicité

loading

Sommaire des Matières pour Cooper Lighting Solutions VWM Vision

  • Page 1 INS # INS # Installation Instructions - VWM Vision Wall Medium Instructions d’installation - VWM Vision Wall moyen Instrucciones de instalación - VWM Vision Wall Medium WARNING WARNING Make certain power is OFF before starting installation Risk of Burn – Disconnect power and allow fixture to or attempting any maintenance.
  • Page 2 Installation Instructions - VWM Vision Wall Medium INSTALLATION Tools Required 3/16” Hex Allen Key, Philip’s screw driver, 1/2” socket wrench. Installation The Vision Wall luminaire has two different types of mounting interface: Standard Mount—mounts to any standard 4” junction box (Included with every fixture) (Figure 1).
  • Page 3 Installation Instructions - VWM Vision Wall Medium Carefully slide the fixture down the keyhole, taking care not to damage the gaskets. Tighten the screws or nuts (Depending on mounting type). ote: Do not caulk around the fixture. 3 1/2” [88.9mm] 10.
  • Page 4 Installation Instructions - VWM Vision Wall Medium Embedded Mounting Kit Thread Power Feed The embedded mounting kit is intended for use when it Mounting Studs lines thru here is desirable to cast the mounting bracket into a poured wall. For orientation to the junction box (Figure 2.) Make sure all power is off.
  • Page 5 Instructions d’installation - VWM Vision Wall moyen AVERTISSEMENT AVERTISSEMENT Assurez-vous que l'alimentation électrique est HORS Risque de brûlure - Débranchez la source d'alimentation TENSION avant de commencer l'installation ou de tenter et laissez refroidir le luminaire avant de procéder à son d'en faire l'entretien.
  • Page 6 Instructions d’installation - VWM Vision Wall moyen INSTALLATION Outils requis Clé Allen 4,76 mm (3/16 po), tournevis Philips, clé à douille de 12,7 mm (1/2 po). Installation Le luminaire Vision Wall possède deux types d’interfaces de montage: montage standard: se monte à toute boîte de jonction standard de 101,6 mm (4 po) (incluse avec tout Trousse pour montage encastré...
  • Page 7 Instructions d’installation - VWM Vision Wall moyen Faites passer les fils d’alimentation par le grand trou central à l’arrière du luminaire tout en alignant les tiges (ou goujons filetés) dans les fentes en trou de serrure à l’arrière (Figure 10). Faites glisser soigneusement le luminaire dans le trou de serrure en faisant attention de ne pas endommager 3 1/2 po...
  • Page 8 Instructions d’installation - VWM Vision Wall moyen Trousse de montage encastré Passez les lignes La trousse de montage encastré est conçue pour Goujons de montage d’alimentation à cet endroit être utilisée lorsque vous souhaitez couler le support de montage dans un mur coulé. Pour l’orientation du luminaire vers la boîte de jonction (Figure 2).
  • Page 9 Instrucciones de instalación - VWM Vision Wall Medium ADVERTENCIA ADVERTENCIA Asegúrese de que la alimentación esté DESCONECTADA Riesgo de quemaduras: desconecte el suministro antes de comenzar la instalación o intentar realizar eléctrico y deje que la luminaria se enfríe antes de cualquier tarea de mantenimiento.
  • Page 10 Instrucciones de instalación - VWM Vision Wall Medium INSTALACIÓN Herramientas necesarias Llave hexagonal de 3/16 ", destornillador estrella, llave de tubo de 1/2". Instalación La luminaria Vision Wall cuenta con dos interfaces de montaje distintos: Montaje estándar: se monta en cualquier caja de conexión estándar de 4 pulg.
  • Page 11 Instrucciones de instalación - VWM Vision Wall Medium Enrosque los cables de alimentación entrantes a través del agujero central grande en la parte trasera de la luminaria mientras que alinea los pernos (o los pernos roscados) con las ranuras del ojo de la cerradura en la parte posterior.
  • Page 12 Instrucciones de instalación - VWM Vision Wall Medium Kit de montaje empotrado Pase líneas de El kit de montaje empotrado está diseñado para su uso alimentación de Pernos de montaje cuando es deseable incorporar el soporte de montaje energía por aquí...
  • Page 13 Garanties et limitation de responsabilité Veuillez consulter le site www.cooperlighting.com pour obtenir les conditions générales. Garantías y Limitación de Responsabilidad Visite www.cooperlighting.com para conocer nuestros términos y condiciones. Cooper Lighting Solutions is a registered trademark. All trademarks are property Cooper Lighting Solutions of their respective owners.