Troubleshooting
The appliance will not start:
The LCD screen does not light up:
Check the mains supply, the condition of the power cord (10).
Check that the On/Off switch (4) is at position 1.
Check that the ammeter protection system has not been triggered due to an overload. (see the paragraph:
"The appliance stops following a motor overload").
Switch the appliance off then on again.
After powering up the 6 key diodes should light up quickly and the screen display "READY". If not, check
on the condition of the wiring and connections in the switch (4), the component support module and the
control panel. (this operation must be carried out by a qualified person).
The LCD screen shows "NOT READY":
This message indicates that one of the keys was already activated before powering up.
Remove any item liable to activate the keys, clean the control panel.
The LCD screen shows "LID OPEN":
Close the safety hood lid (8).
The LCD screen shows "READY":
Switch the appliance off then on again.
After powering up the 6 key diodes should light up quickly and the screen display "READY".
If not, check the connections on the cable connecting the
control panel to the electronic module (this operation must be carried out by a qualified person).
The blade does not rotate:
Check that there are no foreign bodies stuck in the jar.
Check the condition of the drive system (motor and blade).