Product Description; Approvals And Markings; Function - DOLD SAFEMASTER STS YRXKM Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Safety Technique
SAFEMASTER STS
Safety Switch- and Key Interlock System
Basic Unit YRXKM and YRXK01M
YRXKM
Presentation in the deactivated condition:
Actuator removed

Product Description

Switch with separate actuator, disable function and guard locking func-
tion (YRXK01M). When activated the contacts which monitor the disable
position switch. When the actuator is removed, the contacts switch for
actuator monitoring.
To secure separating guards such as safety gates and hoods in machine
and plant engineering.
All technical data in this list relate to the state at the moment of edition. We reserve the right for
technical improvements and changes at any time.
YRXK01M
STS-System Benefits
• EU-Test certificate according to the directive 2006/42/EG, annex IX
• For safety applications up to PLe/Category 4 according
to EN ISO 13849-1
• Modular and expandable system
• Rugged stainless steel design
• Wireless mechanical safeguarding
• Combines the benefits of safety switch, solenoid locking and
key transfer in a single system
• Easy installation through comprehensive accessories
• Protection against lock-in
• Coding level low, medium, high according to DIN EN ISO 14119:2014-03
Features
The units are particularly suitable for applications with:
• Lock-in danger
• Disables the unintentional closing of a separating guard
• Single-channel/ redundant/ diverse safety circuits
• Rugged ambient conditions

Approvals and Markings

Function

YRXKM and YRXKKM based units can be regarded as safety switches
(lock) without interlocking with additional blocking function.
YRXK01M and YRXKK01M based units can be regarded as mechanical
interlock with blocking function.
Switch with separate actuator and actuator insertion blocking
With the The YRXKM version can be removed from the actuator at any
time and switch the actuator contacts. The locking mechanism immedi-
ately blocks the actuator mechanism and prevents the actuator from be-
ing inserted again. The monitoring contacts of the locking mechanism also
switch over. When the magnet is activated, the magnetic contacts switch
and the actuator can be inserted. This switches the actuator contacts.
For the variant YRXK01M, the a key must be inserted into the 01 module
before the actuator can be removed.
Actuator module K is available in accordance with EN ISO 14119:2013
with low and medium coding level. Both versions can optionally be
equipped with an auxiliary release or with an emergency release. Padlock
modules and key modules can also be added. The designation of the in-
terlocking modules with emergency release is YRN module, with auxiliary
release YRH module.
For safety reasons, an escape release cannot be added to this unit.
These units can be connected to the Safemaster STS option module,
which includes command functions and is designed for wiring cross-sec-
tions up to 1,5 m
.
m2
19
SAFEMASTER STS-YRXKM, YRXK01M / 05.12.19 en / xxx
C
US

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Safemaster sts yrxk01m

Table des Matières