DANGER
Ö Even
an
device, such as a submersible pump, must
not be operated for a long period of time
without supervision.
Ö If you leave the device for an extended
period of time, disconnect the pump
electrically.
DANGER
Danger of electric shock !
Ö It is forbidden to use the pump to drain
basins, swimming pools... when there are
people in the water.
Note: Dry running of the pump is possible for a few
minutes. The pump is fitted with automatic reset
thermal protection.
4. MAINTENANCE
DANGER
Ö Disconnect electrical power before
working on the pump !
Maintenance consists of checking and cleaning the
sieve :
1. Turn over the pump.
2. Undo the screws.
3. Clean the sieve.
4. Reassemble sieve by following the opposite
procedure.
5. MALFUNCTIONS, CAUSE AND
TROUBLESHOOTING
DANGER
Ö Disconnect electrical power before
working on the pump !
MALFUNCTION
CAUSE
1. Motor does
Supply voltage
not rotate
missing or wrong
Faulty connection
Defective power
cable
Impeller blocked
Activated motor
protection
(overheating,
blockage, voltage
error or other
defect)
Motor defective
2. Motor rotates,
Impeller clogged or
but does not
worn
convey
Discharge pipe
clogged/hose
kinked
Sieve clogged
automatically
operating
TROUBLESHOOTING
Check power supply
Correct connection
Replacement
(Customer service)
Clean
Check, inform
customerservice
Replacement
(Customer service)
Clean/Replace
Clean/Remove kinks
Clean
MALFUNCTION
3. Feed volume
Pump not properly
too low
ventilated (air
bubble int the
housing)
Discharge pipe
dimensioned too
small
4. The pump
Water too dirty
stops too
Pump blocked
quickly
Thermical protection
on
6. STANDARDS
This appliance complies with the directives
and European standards on electric safety and
electromagnetic compatibility.
7. DISPOSAL
The device must not be disposed of as
household waste and must be disposed
of at a recycling point for electrical
equipment. The device's materials and
components are reusable. The disposal of
electrical and electronic waste, recycling
and recovery of any form of used appliances
contribute to the preservarion of our environment.
8. GUARANTEE
Sanipuddle is guaranteed for two years from the
date of purchase subject to installation, use and
maintenance in accordance with this manual.
11
CAUSE
TROUBLESHOOTING
Remove air by tilting
the pump
Min. diameter of
25 mm
Unplug and clean
Unplug and clean
Check the water
temperature (see 2.2
Technical data and 3.
Operation)
EN