WARNING
If you are not completely familiar
with automotive lift maintenance procedures STOP:
Contact factory for instructions.
To Avoid Personal Injury, permit only qualified lift
service personnel to perform maintenance on this
equipment.
Use only genuine Rotary replacement parts for
repairs.
• Always keep all bolts tight. Check periodically.
• Always raise lift when cleaning floor area.
• Always keep lift clean. Keep bottom weldment dry
and free from corrosives such as salt and cleaning
fluids.
• Daily: Inspect rubber blocks for damage or
excessive wear. Replace as required with genuine
Rotary parts.
• Weekly: Inspect all lift parts for signs of damage
due to overloading and rough handling.
• Weekly: Empty water and refill oil as needed for
filter regulator lubricator.
• Weekly: Check locks and make sure they are clean
and operating correctly. The air cylinder should
allow locking jaws to pivot in-out of lock bar.
• Monthly: Lightly grease sliding surfaces and grease
pins.
• Monthly: Check level of platforms, re-bleed air from
cylinders if needed.
• Semi-Annually: Check fluid level of lift power unit.
Refill if required per lift installation instructions. If
fluid is required, inspect all hoses and seals. Repair
as required.
MAINTENANCE INSTRUCTIONS
• Semi-Annually: Check anchor bolts to ensure they
• If lift stops short of full rise or chatters, check fluid
• Replace all CAUTION, WARNING, or SAFETY related
7
are torqued to 25ft.lbs.
level and purge both cylinders per lift installation
instructions.
decals on the lift if unable to read or missing.
Reorder labels from Rotary Lift.