06
WHISPA III
5000 WM & 9000 WM
8.0 Technical Data
Heating Performance Data
Model
Fan Setting
Boost
Normal
5000 WM
Boost
Normal
Boost
Normal
9000 WM
Boost
Normal
Maximum inlet water temperature 200°F
Heat outputs tested in accordance with BS 4856 Part 1
Electrical supply: 120V 60Hz
Approximate Hydraulic Resistance through Units
g/min
5000
3
4.90
1
0.75
Weight, Water Content and Motor Power
Motor
Model
Power (W)
5000
25
9000
40
9.0 Operating Instructions
This unit is controlled by the switch on the front of the unit.
Ensure the electricity supply is switched on.
Heating Mode
The fan will only operate when
• The central heating boiler is on
• The pump is running
• The system water temperature is greater than 110°F.
Ensure boiler is on, and set timer, boiler controls and room
thermostats as necessary.
• Set fan speed switch to normal position.
• The unit will now run on low fan speed. For satisfactory
operation the mean water temperature should not be below
140°F.
Temperature Control
The room thermostat setting should be gradually adjusted to
obtain the desired temperature.
Flowrate
Entering Water Temperature (°F), Entering Air Temperature (65°F)
(US gpm)
110
120
2040
2516
3
1749
2096
1795
2214
1
1539
1844
3759
4629
3
3266
3916
3308
4073
1
2874
3446
ft wg
9000
6.89
1.07
Water
Unit Weight
Content (fl oz)
(lbs)
5
9.5
11.5
11
Heat Output (Btu/h)
130
140
150
160
2997
3480
3967
4457
2437
2773
3104
3432
2637
3063
3491
3922
2144
2440
2732
3020
5504
6385
7271
8160
4556
5185
5807
6422
4844
5619
6398
7181
4009
4563
5110
5652
Max working pressure: 145psi
" Sweat
1
Water connections:
/
2
Fig.4 Wiring diagram
The fan speed can be set to boost by switching the fan speed
switch to II.
A low speed setting is recommended for normal operation with
the higher speeds for boost heating when required.
Low Limit Operation
The low limit thermostat fitted to the WHISPA III
that the fan stops after the heating system is switched off and
the water flow stops. If left in an operating position the unit will
automatically restart when the heating system is reheated.
Off Position
Set the fan speed selector switch to the off position.
EN
170
180
190
200
4949
5443
5939
6437
3756
4078
4397
4713
4355
4790
5226
5664
3306
3589
3869
4147
9053
9949
10848
11750
7031
7634
8233
8827
7967
8755
9546
10340
6187
6718
7245
7767
®
will ensure