4.
LFE Output/ Link (RCA Type)
To be used to feed additional sub-woofers in addition to the Gold W15 by 'daisy chain' type connection. The output is a link
out only connection and does not provide any form of filtering.
5.
USB Connector
This is provided to update the firmware in the Gold W15.
6.
12 Volt Trigger Input ~ Centre Pin = +12Vdc.
For external power control from AV amplifier/ Receiver to the Gold W15 (2 metre lead supplied). This 12 volt signal is
supplied by the AV amp/ receiver and tells the Gold W15 to turn on from standby mode. This allows a more accurately
controlled method of the auto on/ off function. It is also a lot more energy efficient. The stand by function on the remote
will not be operable when using the +12v trigger.
7.
Power LED
This LED indicates that the mains power is connected and turned on. If the LED is RED, the Gold W15 is in stand-by mode
waiting to receive an audio signal, an instruction from the encoder/ remote or a signal from the 12v trigger. If it is green,
the unit is operational and the display will show a single red dot (default operational display).
8.
Voltage Selection Switch
Factory preset to suit the voltage of the country of origin. This should not be adjusted.
9.
Mains Power Switch
Mains 'rocker switch' providing overall power off and on/ auto. In the on/auto mode, the unit will turn on when an input
signal is sensed or the encoder/ power button on remote pressed, and will turn off after 10 minutes when the signal is
removed (source turned off). Alternatively, when using the 12v trigger (see above), when the source is turned on or off.
10. IEC Mains Power Connector/Fuse Location
The Gold W15 is supplied with a two-pin mains input socket for connection to the mains supply. Use ONLY the appropriate IEC
mains lead provided with the product. Also fitted is an external mains fuse. If a fuse blows during operation a spare fuse is
provided within the fuse holder for replacement. If you wish to change the fuse, you can do this by removing the IEC mains
lead and carefully levering out the original fuse from its holder below the IEC mains input socket (10a, opposite). If the fuse
blows again it is advisable to seek help from an authorised service agent. DO NOT attempt to re-fit a further fuse as this
could result in serious damage to the amplifier unit.
11. Display
The default operating display will show a single dot in the middle. When powering up it will run through a set cycle showing
the input and the preset being used. For full details of the menu system, please refer to page 10
12. LEO Microphone Input
Used to set the sub woofer up to adjust for the room acoustics. Refer to page 9.
13. Push-Turn Control Button Encoder
This gives you control of your Gold W15. You can adjust the volume (by turning the control button) and enter the menu
system. Pushing the rotary encoder allows access of the menu system (refer to page 10).