Command Format
The command between this unit and the computer consists of "Header", "Unit ID", "Command", "Data" and "End".
Header (1 byte), Unit ID (2 bytes), Command (2 bytes), Data (n bytes), End (1 byte)
0
Header
This binary code indicates the start of communication.
Binary Code
21
Operating command
3F
Reference command PC " This unit
40
Response command
06
ACK
Unit ID
This is a code that specifies the unit. The binary code is fixed at "8901".
Command and data
Operating command and data (binary code)
Command
Type
0000
Connection
Check whether communication is
check
enabled between this unit and the
PC during standby.
5057
Power
During standby
supply
31: Turns on the power
When power is on
30: Turns off the power (Standby
mode)
4950
Input
When power is on
36: HDMI 1
37: HDMI 2
5243
Remote
Sends the same code as the
control
supplied remote control.
0
End
This code indicates the end of communication. The binary code is fixed at "0A".
Type
PC " This unit
This unit " PC
This unit " PC (returns to PC after the command is accepted without
error)
Description
"Remote Control
Code"p. 72
Description
Operating command and data (binary code)
Command
Type
5057
Power
During standby or when power is
supply
on
30: Standby mode
31: When power is on
32: In the Cool-down mode
34: When error occurs on this unit
4950
Input
When power is on
36: HDMI 1
37: HDMI 2
Description
71