3
Product description
Controller for use in safety-critical tightening.
The controller is primarily used as a control and monitoring
unit for one or more tools at a workstation. Depending on
the peripheral devices that are procured, the controller can
also be installed outside of the work environment.
Software is already installed on the controller. The tighten-
ing settings must be carried out by a qualified person using
the Primary-/Master-controller or remote PC software
(mProRemote) in order to start fastening work. For further
information regarding software operation, please reference
the Programming Manual mPro400GCD.
The secondary controller is an extension module to the pri-
mary/master controller and is needed to operate an addi-
tional corded tool.
4
Technical Specifications
Ambient Conditions
Features
Operation Site
Ambient Temperature
Storage Temperature
Type of Cooling
Relative Humidity
Working Height
Protection Class
DIN EN 60529
Protection Class
DIN EN61140
(VDE 0140-1)
Degree of Contamination
EN 61010
Transient Overvoltage
EN 61010
Maximum Shock
DIN EN 60068-2-27
Maximum Vibration
DIN EN 60068-2-5
1. Note the derating. See the System Handbook NeoTek
Power Supply
Features
Supply Voltage,
Single Phase
Rated Supply Current
Frequency
Apex Tool Group
Data
Indoors
1
0...45 °C
-20...70 °C
Convection (self-cooling)
10...90 %, No Condensa-
tion
Up to 3000 m
Above Sea Level
IP42
I
2
CAT
15 G
59.6–160 Hz: 2 G
Data
1
100–240 VAC ± 10%
1–2 A
50/60 Hz
P2349HW | 2019-08
Features
Peak Current
Rated Power
Idling
1. When operating outside the allowable voltage limits,
the integrated power supply enters a protection mode
and switches off. This protection mode can be reset
by restarting the nutrunner controller.
Normative references
For product-relevant EC Directives, as well as the stan-
dards complied with, see the EC Declaration of Conformity.
Certificates
Issuing agency
Certificate No.
Tested in accordance
with
Certificate No.
Tested in accordance
with
Certificate No.
Tested in accordance
with
System Data
Features
Data
System Functions
Battery Buffered Real Time Clock, Buffer
Time: 20 Years (at 20 °C)
Display
LC Display With Touchscreen,
7" TFT Liquid Crystal Display,
Resolution 800 x 480, Connection To
Panel & Touch Possible
Operating System
Linux Operating System
out Mechanically Moving Drives, No UPS
Required
HMI
Virtual Keyboard for Alphanumeric Inputs
(Human Machine
Interface)
1. This product includes several open source software
packages, distributed under various open source
licenses. Additional information about the open source
packages and licenses can be found at http://soft-
ware.apextoolgroup.com/oss-legal/
Weight
Model
mPro400GCD-S
mPro400GCD-SH
Data
16 A
1600 VA max.
160 VA
TÜV SÜD AG
U8 78313 0005
•
UL 61010-1:2012/
R:2016-04
•
CAN/CSA–C22.2
No.61010-1:2012/
U2:2016-04
N8A 78313 0007
•
EN 61010-1:2010
DE3-30943
•
IEC 61010-1:2010
1
, Bootable With-
Weight
lb
kg
28.2
12.8
9
1
EN