Pin Assignment; Items Delivered - Cleco mPro400GCD-S Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

1
EN
5

Pin Assignment

This chapter describes the Cleco Production Tools specific
connectors. Standard plugs are not considered. All connec-
tions are short-circuit proof.
X21 – TSnet System Bus Out
Interface port for TSnet cable.
Pin
Signal
1
Tx +
2
Tx -
3
Rx +
4
RX -
5
0 VDC
6
0 VDC
7
+24 VDC
8
+24 VDC
X22 – TSnet System Bus In
Pin
Signal
1
Tx +
2
Tx -
3
Rx +
4
RX -
5
0 VDC
6
0 VDC
7
+24 VDC
8
+24 VDC
X23 – Supply
Description
Connector with Fuse Holder
2-Pin, 5 × 20 mm, 16 A
Slow-Blow
Note
Use plug locking mechanism.
See Quick Installation Guide.
X24 – Tool Cable 30/50E×N... Series
Pin
Signal
1-3
Power
4
PE
(functional
ground)
5
Tool bus
10
8 Pin M12 Circular Connector
X-Coded
3
2
1
4
8
5
6
7
8 Pin M12 Circular Connector
X-Coded
3
2
1
4
IEC Connector C14
M23 circular connector
5
3
1
2
4
P2349HW | 2019-08
X25 – Tool Cable 18/48E×E... Series
Pin
Signal
1-3
Power
4
PE
5
Signals
6

Items Delivered

Check delivery for transit damage and ensure that all items
have been supplied:
Controller
EC Declaration of Conformity
Hardware Description
SP-1500
Warranty
Mating Connector
Power Cable
EU 230 VAC
Order no.
541683-03
Plug Locking
Mechanism
Order no.
544004-1
ECTA Circular Connector
Push-Pull
1
4
2
3
5
Power Cable
USA 115 VAC
Order no.
541683-01
Power Cable
USA 230 VAC
Order no.
541683-02
Apex Tool Group

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mpro400gcd-sh

Table des Matières