Comfee CP05S3WBA1RCM Guide De L'utilisateur page 19

Climatiseur portatif
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

thermostat allowing for the precise temperature
control at its location. To activate the Follow Me/Temp
Sensing feature, point the remote control towards the
unit and press the Follow Me/Temp Sensing button.
The remote control will send this signal to the air
conditioner until press the Follow Me/Temp Sensing
button again. If the unit does not receive the Follow
Me/Temp Sensing signal during any 7 minutes interval,
the unit will exit the Follow Me/Temp Sensing mode.
NOTE: This feature is unavailabe under FAN or DRY
mode.
AUTO-RESTART
If the unit breaks off unexpectedly due to the power
cut, it will restart with the previous function setting
automatically when the power resumes.
AIR FLOW DIRECTION ADJUSTMENT
Adjust the air flow direction manually:
· The louver can be set to the desired position manually.
· Do not place any heavy objects or other loads on the
louver, doing so will cause damage to the unit.
· Ensure the louver is fully opened under heating
operation.
· Keep the louver fully opened during operation.
WAIT 3 MINUTES BEFORE RESUMING OPERATION
After the unit has stopped, it can not be restarted
operation in the first 3 minutes. This is to protect the
unit. Operation will automatically start after 3
minutes.
POWER MANAGEMENT feature(On some models)
Under cooling operation, when the ambient
temperature is lower than the setting temperature for
a period of time, the unit will be automatically operate
power management feature. The compressor and fan
motor stop. When the ambient temperature is higher
than the setting temperature, the unit will be
automatically quit the power management feature.
The compressor and (or) fan motor run.
WATER DRAINAGE
· During dehumidifying modes, remove the drain plug
from the back of the unit, install the drain connector
(5/8" universal female mender) with 3/4" hose(locally
purchased). For the models without drain connector,
just attach the drain hose to the hole. Place the open
end of the hose directly over the drain area in your
basement floor.
Continuous
drain hose
Remove the
drain plug
NOTE: Make sure the hose is secure so there are no
leaks. Direct the hose toward the drain, making sure
that there are no kinks that will stop the warter
flowing. Place the end of the hose into the drain and
make sure the end of the hose is down to let the water
flow smoothly. When the continuous drain hose is not
used, ensure that the drain plug and knob are installed
firmly to prevent leakage.
· When the water level of the bottom tray reaches a
predetermined level, the unit beeps 8 times, the
digital display area shows "P1" . At this time the air
conditioning/dehumidification process will
immediately stop. However, the fan motor will
continue to operate(this is normal). Carefully move
the unit to a drain location, remove the bottom drain
plug and let the water drain away. Reinstall the
bottom drain plug and restart the machine until the
"P1" symbol disappears. If the error repeats, call for
service.
NOTE: Be sure to reinstall the bottom drain plug firmly
to revent leakage before using the unit.
Bottom drain
plug
19

Publicité

Chapitres

Table des Matières
loading

Table des Matières