J. poWEr up thE controllEr thE firSt tiME
Start up
Language chosen:
English
Select language.
k. chEck Motor DirEction
Give a manual down
command for zone 1.
Solar protection
going down?
Yes
Give a manual up
command for zone 1.
No
Solar protection
Check cabling.
going up?
Yes
Repeat for zone 2.
Then done.
l. SEt Motor running AnD tilting tiME.
Enter the time (
down running time
position to the position where you want the solar protection to move to when e.g. sun and
timer functions are active.
If blinds are used also enter the time (
closed to the angle you want when the sun function is active. As a rule of thumb the time
up (up running time) should be double that of the down time (down running time).
To test your running and tilt times make sure that the solar protection is in the fully up/in
position and then give a manual down command.
Set running time
25 sek
Start up
Used network mode:
If not correct, change
before you continue!
Next
IMPORTANT: If you change the network mode,
you must power the controller off and on.
No
Give a manual
up command.
No
Solar protection
going down?
Yes
Switch up and down
cable to motor/relay.
) needed for the solar protection to move from fully up/in
) needed for the slats to move from fully
tilt time
Set tilting time
25 sek
Start up
IB
Set clock
Set weekday
Next
Check cabling.
1 sek
Motor
Set down running time...
Set tilt time...
Set up running time...
10:21
Monday
Next
7