2.6.2 Cleaning agents
•
To achieve optimum cleaning and service life of the machine we recommend using Wetrok chemical products. No guarantee or liability will be
accepted for damage or consequential damage resulting from the use of other products.
•
When using cleaning and care products, observe the producer's hazard warnings.
•
and wear safety goggles, protective gloves and protective clothing, if required.
•
The use of foaming, highly inflammable, combustible, health-threatening, corrosive or irritant substances is prohibited.
•
Use only water and cleaning agents suitable for the machine.
•
Do not use any aggressive or inflammable cleaning agents for cleaning the machine!
2.6.3 Limiting values
•
Do not exceed gradients of 2%for work and 8% for transport or when machine is stationary. After having finished cleaning,
the machine must be secured against rolling away by turning the machine off and removing the key from the key switch.
•
Do not move the machine on slopes of more than 8%.
•
Do not reverse the machine down slopes of more than 8%.
•
Do not turn or drive the machine across slopes of more than 2%.
•
After having finished cleaning, the machine must be secured against rolling away by removing the key from the key switch.
In addition, press the emergency stop button. Only then, the brakes are safely applied.
•
Air humidity during operation must be between 30-95%.
•
Noise emission is below 70 dBA.
2.7 Emergency stop
The machine is equipped with a red emergency stop button.
If obstructions appear suddenly, the machine can be brought to a standstill by:
•
Releasing the throttle handle and/or braking.
•
Or by pressing the red emergency stop button.
•
Or by removing the key from the key switch.
•
The same applies when reversing.
2.8 Maintenance, safety, service
Wetrok products are safety-tested at the factory. To ensure their operational safety and to maintain their value, a service must be carried out once
every twelve months or after 400 hours of operation.
Servicing may be done only by a Wetrok service department or by approved specialists.
General:
•
When cleaning or maintaining the machine, exchanging accessories and spare parts or switching to another function, turn off the drive,
remove the key from the key switch and press the emergency stop button.
•
Do not clean machine with high-pressure or steam-pressure cleaners or liquid spray.
•
To ensure trouble-free running, the fresh water tank should be cleaned regularly with Wetrok Ketovapor CIP3 (5%).
The time taken for Wetrok Ketovapor CIP3 to act depends on the amount of contamination in the tank.
Batteries:
•
Batteries contain corrosive sulphuric acid. Not to be taken internally, corrosive! Avoid contact with skin and eyes.
Observe manufacturer's instructions without fail!
•
Charging wet-cell batteries produces electrolytic gas. There is the risk of serious injury! battery compartment open,
empty tank beforehand and open out! Keep area well ventilated during charging.
•
Maintenance-free and wet cell batteries may be charged using only a suitable charger.
•
Never have naked flames or incandescent object near the batteries. Avoid sparks near batteries!
•
Strictly no smoking.
•
Do not open maintenance-free batteries. Do not top up with distilled water.
•
Do not touch battery terminals.
•
Battery terminals are heavily insulated to prevent shorting by metallic bridging (e.g. spanners). Do not remove insulation.
•
Laying conductive objects on the batteries (e.g. spanners) is prohibited.
•
Do not clean machine with high-pressure or steam-pressure cleaners or liquid spray.
•
Damaged electric cables may be replaced only by specialists.
Accessories and spares:
•
Use only Wetrok spares, accessories and components.
2.9 Storage, transport
•
If machine is not used, store in a dry space under normal ambient conditions.
•
First empty fresh and dirty water and clean out tank.
•
Keep tank lid open.
•
For long term storage of the machine, disconnect the battery cable.
•
Charge batteries every month when storage is prolonged.
•
Temperature must not exceed 50°C when transporting and storing machine.
•
At temperatures below 0°C, run machine for a short while with anti-freeze added to the water, and then empty.
•
When transporting over further distances, machine must be suitably secured and packaged.
•
Activate brake switch when pushing machine in a switched-off state.
38