Power Shot
Pressing the power shot
button causes water
quantity, brush pressure
and suction to run at full
power for 6 seconds for
local areas of heavy
soiling.

Accessories and consumables

Pad-drive disk

Problem solving

FAULT
Machine does not work
Cleaning action inadequate
No suction or suction inadequate
Streak formation
No supply of cleaning agent or water, or supply
inadequate
Laser not functioning or poorly visible
Batteries not charged or charge is too low
Suction bar falls off (too easily)
Long Running System (LRS):
Pressing the LRS button causes water
quantity, brush pressure and suction to be
reduced to economy operation. This mode
is recommended for cleaning smooth and
slightly soiled floors. This saves water
and cleaning agent and at the same time
increases service time.
Polypads
CAUSE
Emergency stop button pressed
Fuse or overvoltage protection tripped
Machine switched off automatically
(Power down function)
Magnetic brake does not disengage
Brush / pad badly worn
Dosing / water too low
Suction nozzle or suction hose clogged
Suction hose not connected
Tank lid not closed or seal defective
Sealing lid at outlet hose not correctly screwed on or
seal faulty
Turbine switched off or at reduced level
Suction lips contaminated or worn
Suction nozzle pad incorrectly adjusted
Tubes clogged
Fresh water filter clogged
Water supply closed
Chemicals supply closed
No fresh water in tank (Water pump operation audible)
Laser lens is soiled
Laser is incorrectly adjusted
Unsuitable conditions of floor or lighting
Duration of battery charging too short
End of battery service life reached
Jams during mounting in pulled-up state
33
Scrubbing brush
Supernylon
SOLUTION
Unlock emergency stop button
Carry out reset with key switch OFF/ON
Carry out reset with key switch OFF/ON
Check main controller plug
Replace brush / pad
Increase dosing / water
Remove clogging
Connect suction hose
Close tank lid correctly or replace seal
Check seal, screw on lid firmly,
replace if necessary
Switch on turbine or increase to full suction power
Clean or replace suction lips
Correctly adjust height and angle of suction nozzle
(should be done by specialist)
Rinse fresh water tank and tube system with clean
water
Clean fresh water filter
Open or adjust water supply
Open chemicals supply and/or restart dosing
Fill with fresh water
Clean carefully with cleaning cloth
Readjust laser attachment
(should be done by specialists)
---------------------
Observe the required charging duration
Change batteries (observe safety instructions)
Screw on suction bar in lowered state
(select PGM1, 2 or 3, this lowers the lifting mechanism)
Drive-assistant laser
When appliance is moved forwards
the integrated laser system
automatically projects a 1-metre
line to the right in front of the
brush housing. This makes drive
positioning of the machine easy,
thereby avoiding cleaning the
same spot twice (no overlapping of
cleaning tracks).
Scrubbing brush
Tynex (very hard)
EN