Product Operation; Global Operation; Park Mode; Command Mode - Adeunis RF sigfox ANALOG PWR Guide Utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

sigfox ANALOG PWR - Guide utilisateur / User guide version V1.2.0

2. PRODUCT OPERATION

2.1. Global operation

Important: Adeunis RF use the most significant byte first format.
The product has several operating modes:

COMMAND MODE

2.1.1 PARK mode

The product is delivered in PARK mode, it is in standby mode and its consumption is minimal. To switch the product out of the Park* Mode pass
a magnet across it for a duration higher than 6 seconds. The green LED illuminates to indicate the detection of the magnet and then flashes
quickly during the product starting phase.
The device then sends its configuration and data frames (see paragraph 4.1).
2.1.2 COMMAND mode
This mode allows the user to configure the registers of the product.
To enter this mode, connect a cable to the micro-USB port of the product and enter the command mode by an AT command (see paragraph 3).

2.1.3 OPERATING mode

There are two possible modes of operation:
TEST mode:
This mode allows the user to perform tests of the product more quickly by reducing the time scales of production mode and modifying the beha-
viour of the LEDs (see paragraph 2.2.5).
PRODUCTION mode:
This mode allows the user to operate the product in its final use. It should allow a maximum of autonomy to the product.
To switch from one mode to the other the user changes the value of a register
Command sending
by serial link
PRODUCTION MODE
COMMAND MODE
TEST MODE
PARK MODE
Presence of a magnet
on the product >6s
OPERATING MODE
COMMAND MODE
The return to the produc-
tion mode is done by the
ATO command or by dis-
connecting the USB cable
Page
51
EN
of 73

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Arf8201aa

Table des Matières