Laser Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LR8
Article number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 601 K69 J11
Working range
Receiving angle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90°
Measuring accuracy
– "Fine" adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .±1/32" (±1 mm)
– "Coarse" adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±1/8" (±3 mm)
Operating temperature . . . . . . . . . . . . . . . .14 °F . . . .+122 °F (–10 °C . . .+50 °C)
Storage temperature . . . . . . . . . . . . . . . . . . -4 °F . . .+158 °F (–20 °C . . .+70 °C)
Max . altitude . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6560 ft (2000 m)
Relative air humidity, max . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90%
Pollution degree according IEC 61010
Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 x1 .5V LR6 (AA)
Operating time, approx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 h
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0 .33 lb (0 .150 kg)
Degree of protection . . . . . . . . . . . . . . . IP 54 (dust and splash water protected)
Dimensions (length x width x height) . . . 2 .9" x 1 .1" x 5 .4" (73 x 28 x 137 mm)
1) The working range can be decreased by unfavorable environmental
conditions (e .g . direct sun exposure) .
2) The angular accuracy between the 45° laser line and the 90° laser line is
max . ±5/32 @ 30 ft (+/-0 .4 mm/m) .
3) Conductive pollution occurs, or dry, non-conductive pollution occurs
which becomes conductive due to condensation which is expected . In such
conditions, equipment is normally protected against exposure to direct
sunlight, precipitation, and full wind pressure, but neither temperature nor
humidity is controlled .
Please observe the article number on the type plate of your tool .
The trade names of the individual tools may vary .
The tool can be clearly identified with the serial number 14 on the type plate .
2610050387 03-18 LR8.indd 9
Technical Data
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15'-165' (5-50 m)
1)
2)
3)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
-9-
3/20/18 3:08 PM