Télécharger Imprimer la page

hager RTN500X Manuel page 8

Publicité

Les langues disponibles

Les langues disponibles

RTN500X
Introduction / Connection and power supply
Table of contents
Introduction
Connection and power supply
Factory settings
Safety instructions
The installation and assembly of electrical equipment may only be carried out by an electrician in compliance with applicable in-
stallation standards, directives, regulations, safety and accident ordinances for the local country. When working on systems with a
230 V~ power connection, the safety requirements of DIN VDE 0100 must be met. Failure to comply with the instructions can cause
damage to the device, fire or other dangers. These instructions are a component of the product and must remain with the end cus-
tomer.
System information and intended use
This device is a product of the IP door intercom system and can only be used within the defined installation scenarios. Detailed
technical knowledge from IP training is assumed in order to understand them. The function of the device depends on its configura-
tion. You can find more information about the specific functional scope in the corresponding application descriptions in the product
database.
Connection and power supply
NET
WORK
INPUT
PE
0V
S3B
+UB
GND
+5V
REL1.1
REL1.2
LEDB
REL2.1
Z1
REL2.2
Z2
+24V
Z3
ELAN
Z4
GND
GND
NET
NET
WORK
WORK
OUTPUT
INPUT
Via IP door speaker module
with PoE switch
The IP camera module is connected to
the OUTPUT port of the IP door speak-
er module using the included network
cable. Through door speaker module
using the INPUT port to the PoE switch.
The IP camera module is connected to
hardware and power through the IP
door speaker module.
8
8
Installation concepts and configuration
8
Quick start configuration with RTD110X
9
Expert configuration
NET
WORK
INPUT
PE
0V
+UB
REL1.1
REL1.2
REL2.1
REL2.2
+24V
ELAN
GND
NET
+
-
WORK
OUTPUT
L
N
Through IP door speaker module
with 28VDC power supply
Connect terminals 0V and +UB on the IP door speaker
module to a 28VDC power supply (HAGER RED013X)
and connect the INPUT port to an Ethernet switch
via a network cable (CAT5 or better). The IP camera
module is connected to the OUTPUT port of the door
speaker module using the included network cable,
and is thus connected to the network as well as sup-
plied with power.
Subject to technical changes
S3B
GND
+5V
LEDB
Z1
Z2
Z3
Directly on PoE switch
Z4
GND
(IEEE 802.3af-compliant)
NET
WORK
INPUT
The IP camera module is con-
nected to the PoE switch via
a network cable on the INPUT
port. The power supply in this
case comes through the data
lines (end span). Operation with
a PoE injector is not possible
since in these devices power is
generally supplied through the
unused lines (midspan).
In this wiring arrangement, two
network lines to the door station
may be needed. Advantage:
Security functions of the switch
(e.g. MAC freeze/intrusion lock)
can be used.
9
10 - 11
12 - 13
NET
WORK
INPUT
www.hager.com

Publicité

loading