Télécharger Imprimer la page

SFA SANIACCESS PUMP Notice D'installation page 11

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
UK
1
DESCRIPTION
This lifting station is manufactured in a
factory which is quality certifi ed to ISO
9001(2000) accredited by AFAQ.
Installed and used correctly, the unit
will give consistent and reliable service.
This device is not designed for
persons (including children)
with limited physical, sensory or
mental abilities, or those with minimal
experience and knowledge, unless
they are monitored and are given
the necessary instructions for using
the device, with the help of a person
responsible for their safety. Monitor
children and make sure they do not
play with the device.
2
APPLICATIONS
This device is a compact lifting station
designed to evacuate waste water
from private dwellings (except for water
coming from WC's).
3
INSTALLATION
The unit should be installed in the
same space as the connected faci-
lities and should be accessible for
possible service.
The fi tting and working of your ap-
pliance must meet local regulations
and the EN 12056-4 standard.
CONNECTION TO THE ELECTRICAL
SUPPLY
The electrical installation
should be carried by a quali-
fi ed person.
The unit should be connected to a fully
earthed electrical supply. All wiring must
conform to BS7671, 1992 require-
ments for electrical installations. The
unit requires a 220/240V single phase
AC 50 Hz supply (UK specifi cation). Do
not connect the unit to a conventional
plug and socket. It must be wired into
a fused, unswitched, fi xed wiring
connector fi tted with a 5 amp fuse.
The wires in the mains lead are coloured
in accordance with the following code:
Brown - Live
Blue - Neutral
Green/Yellow – Earth
Warning: Ensure the electricity is
turned OFF at the main switch board
before wiring to connector.
All work on cable, pressure chamber
and motor should only be carried out
by a qualifi ed Sanifl o servicing agent,
as special tools are required.
This appliance conforms to EN
12050-3 and the European stan-
dards concerning electrical safety
and electromagnetic compatibility.
4
COMMISSIONING
THE UNIT
Once
electrical
and
connections have been made, check
6
FAULT FINDING / REMEDIES
If the problem cannot be easily remedied in this way, please
call our Service organisation.
ALL WORK INVOLVING DISMANTLING OF THE APPLIANCE
MUST BE CARRIED OUT BY AN APPROVED REPAIR AGENT
IN ALL CASES, YOU MUST DISCONNECT
THE MACERATOR FROM THE POWER SUPPLY
SYMPTOMS
• The motor does not activate
• The motor intermittently
activates
• The motor operates normally, but
continues to run for a long time
• The unit stops
• Cloudy water comes up into
the shower basin (units with
side inlets)
7
GUARANTEE
2 years guarantee as from its date of purchase subject to correct installation and
correct use.
5
that all seals, and connections are
watertight.
Check both the discharge pipework
from the unit and the other sanitary
appliances connections.
5
MAINTENANCE
WARNING !!!
If away for a long period, we recom-
mend that you turn off the water sup-
ply to the WC served
by the unit.
CARE OF YOUR UNIT
In order to remove scale and clean
plumbing
the lifting station, use a household
descalent (like SANIFLO Descaler).
PROBABLE CAUSES
• The electrical power supply
is not active
• The electrical power supply is
defective
• The motor or the control system
is defective
• The connected sanitary devices
are leaking
• The non-return valve is faulty
• The length or height of the
installation is over the
specifi cation, or there are too
many bends/elbows
• The lifting station cover plate is
occluded
• The unit has been running for
too long (thermal cut-out)
• Shower installed too low as
compared with the lifting station
• Hinged side inlet discs
clogged up
REMEDIES
• Restore the electrical supply
• Check the electrical power
supply
• Otherwise, ask an approved
repair agent to intervene
• Check the installation upstream
• Clean or replace the non-return
valve
• Check the installation
• Otherwise, ask an approved
repair agent to intervene
• Wait for reset, then ask an
approved repair agent to
intervene
• Check the installation
• Clean the hinged discs
• Otherwise, ask an approved
repair agent to intervene