cap pressure test

For diagnosing:
Proper function of pressure cap
set-up & procedure:
1. Ensure the cooling system is cool and not pressurized.
Carefully remove the radiator or coolant bottle pressure cap.
2. Select the correct Cap Adapter for the application. Refer to the
Adapter Selection Guide included in the kit.
3. Apply water or coolant to the rubber gasket and/or o-ring
on the cap, and install the cap onto the adapter.
4. Install the Pressure Pump onto the Cap Adapter using the
quick-connect. Make sure the quick-connect sleeve snaps
forward to lock the connection.
5. Determine the rated cap pressure. It will be printed on the
cap or in the vehicle manual. Compare this value to the
chart below (see Chart A) to determine the acceptable
pressure test range.
6. Operate the Pressure Pump until the cap releases pressure.
The pressure should relieve when the arrow is in the colored
band on the gauge face corresponding to the test range of
the cap. Discard and replace the cap if it fails to relieve pressure
in the indicated range.
7. When testing is complete, release the pressure by pressing
the Pressure Relief Valve located on pump hose near the
quick-connect coupler.
8. Disconnect the components, clean, and store them properly.
lincoln industrial standard Warranty
LIMITED WARRANTY
Lincoln warrants the equipment manufactured and supplied by Lincoln to be free from defects in material and workmanship for a
period of one (1) year following the date of purchase, excluding therefrom any special, extended, or limited warranty published by Lincoln. If equipment is
determined to be defective during this warranty period, it will be repaired or replaced, within Lincoln's sole
discretion, without charge.
This warranty is conditioned upon the determination of a Lincoln authorized representative that the equipment is defective. To obtain repair or replace-
ment, you must ship the equipment, transportation charges prepaid, with proof of purchase to a Lincoln Authorized Warranty and Service Center within
the warranty period.
This warranty is extended to the original retail purchaser only. This warranty does not apply to equipment damaged from accident, overload, abuse, mis-
use, negligence, faulty installation or abrasive or corrosive material, equipment that has been altered, or equipment repaired by anyone not authorized by
Lincoln. This warranty applies only to equipment installed, operated and maintained in strict accordance with the written specifications and recommenda-
tions provided by Lincoln or its authorized field personnel.
THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED
TO, THE WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
In no event shall Lincoln be liable for incidental or consequential damages. Lincoln's liability for any claim for loss or damages arising out of the sale,
resale or use of any Lincoln equipment shall in no event exceed the purchase price. Some jurisdictions do not allow
the exclusion or limitation of incidental or consequential damages, therefore the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights. You may also have other rights that vary by jurisdiction.
Customers not located in the Western Hemisphere or East Asia: Please contact Lincoln GmbH & Co. KG, Walldorf, Germany, for your warranty rights.
Lincoln Industrial Contact Information:
To find Lincoln Industrial's Nearest Service Center call the following numbers, or you may also use our website.
Customer Service
Americas:
One Lincoln Way
St. Louis, MO 63120-1578
USA
Phone +1.314.679.4200
Fax +1.800.424.5359
Form 823094
314-679-4200
Europe/Africa:
Heinrich-Hertz-Str 2-8
D-69183 Walldorf
Germany
Phone +49.6227.33.0
Fax +49.6227.33.259
chart a: cooling system cap pressure test ranges
Rated Pressure (PSI)
4
7
10
13 or 14
15 or 16
18
20
30
Website:
lincolnindustrial.com
Asia/Pacific:
25 Int'l Business Park
#01-65 German Centre
Singapore 609916
Phone +65.562.7960
Fax +65.562.9967
Pressure Test Range (PSI)
3 - 5
6 - 8
9 - 11
12 - 16
14 - 18
16 - 20
18 - 22
28 - 30
Page Number - 6