Pentair Pentek
Input Specification:
- AC grid operating voltage
- Maximum AC input current:
- Maximum solar open circuit voltage:
- Maximum solar PV current in series:
- Earth-ground connected to chassis
Suitable for use on a circuit capable of delivering not more than 5000 rms symmetrical
†
amps, 230 volts maximum.
DC PV input terminals shall only be connected to listed photovoltaic modules and panels
††
that comply with UL 1703.
Suitable for use on a circuit capable of delivering not more than 13.5 rms symmetrical
†††
amps, 400 volts maximum.
Output Specification:
- Maximum output current:
- Maximum output current:
- Maximum power sustained:
Protections:
- Input AC grid over-current: 12A fused terminal block
- Short-circuit, ground-fault, over-temperature, overload, over-voltage, over-current
- Automatic dry well protection and pump locked rotor protection
Integral solid state short circuit protection does not provide branch circuit protection.
Branch circuit protection must be provided in accordance with the National Electrical
Code(NEC) and any additional local codes.
ELECTRICAL
AC source operating voltage: 115-230V
AC Source phase & frequency: 1 phase only!
Solar PV open circuit voltage: 400V
Max PV panel current in series: 9A
Max Single phase AC motor current: 10A
Max Three phase AC motor current: 8A
Carefully check the motor load specifications, AC source voltage available and solar PV
array maximum power point voltage to set up the system properly using this manual!
If 120-Vac is used as AC grid input, maximum load that can be connected is 1400W!
P1063 (10-03-19)
Solar Drive Specifications
*
:
†
50/60Hz
WARNING:
115 Vac 60 Hz, 1-phase
230 Vac 50/60 Hz, 1-phase
12 Amps
400 Vdc
††
9 Amps
†††
10 Arms (1-phase motors)
8 Arms (3-phase motors)
2500 W
MECHANICAL
Degree of protection: TYPE 3R
Enclosure material: Aluminum
Operating temperature: -40 ̊ C to 40 ̊ C
Dimensions: 18"x10"x5"
AC Source Terminals: AWG #10-16
Solar Terminals: AWG #10-16
Motor terminal: AWG #10-16
Float Sensor terminals: AWG #14-20
5