Once the system is wired (per Figure 8), the power conductors wired to the DIN rail
terminals inside the Pentair Pentek Solar Drive should be tightened with torque values of:
– Solar PV and motor load conductors: 10 lb-in
– AC source conductors: 10 lb-in
The cable glands (cord grips) on the bottom of the enclosure should be used as follows:
– 1/2 inch cord grips should only be used with a cord that is 0.280-0.455 inch
outer diameter.
– 3/4 inch cord grips should only be used with a cord that is 0.455-0.705 inch
outer diameter.
When all conductors are wired into the controller, the cover (enclosure door) should be
replaced and tightened using the cover screws to 2-3 in-lb or equivalent.
Terminal 1
(Yellow)
Terminal Aux
(Grey)
Yellow
Red
Black
Red
Float Switch/
Other Sensors
Single phase motor loads should be wired as shown in Figure 8. 3-wire motors should be wired
so that Common Lead is wired to Phase A, Starting Winding to Phase B and Main Winding to
Phase C. Use DIP Switch 8 for proper single phase motor selection.
IMPORTANT:
Three Phase Motor
Terminal 1 (Yellow): YELLOW wire
Terminal 2(Red): RED wire
Terminal 3(Black): BLACK wire
10
Solar Drive Wiring Instructions
*
3-Wire,
Single
Phase
Motor
Figure 8: Wiring Inside the Pentair Pentek Solar Drive
AC Source
Three
Solar PV
Phase
Motor
Single Phase 3-wire Motor
Terminal 1(Yellow): YELLOW wire – common motor lead
Terminal Aux(
): RED wire – start motor lead
Grey
Terminal 3(Black): BLACK wire – main motor lead
Terminal 2
(Red)
Terminal 3
(Black)
Red
Black
Red
Black
System
Ground
P1063 (10-03-19)