DIP Switch 11- Max Frequency: See Figure 15. Offers
an option for setting the maximum frequency for motor
operation. This can be helpful to reduce pump flow.
If DIP switch 11 is OFF (down) (default) the maximum
motor load frequency is set to 60Hz. If ON (up), the maximum
frequency is set to 55Hz for standard 60Hz AC motors. If the
Pentair Pentek Solar Drive is controlling a 50Hz motor, defined
by DIP switch 3, then the OFF position is 50Hz, while the ON
position indicates 45Hz maximum frequency operation.
DIP Switch 12 – Pressure Regulation: Unused
The Pentair Pentek Solar Drive controller can be turned ON or OFF remotely by using a
digital input or by using a standard float switch. There is a float switch terminal block
(Figure 6 on page 8) where digital signal wires are connected.
If Digital Inputs 1 and G experience a short circuit, the Pentair Pentek Solar Drive
automatically turns off. Similarly, if Digital Input 2 and G experience an open circuit, the
Pentair Pentek Solar Drive automatically turns off. There are numerous remote sensors
that can be used: float switch, pressure switch, flow switch, water level sensor, dry run
protection, etc. Ask your dealer about configuring sensors and switches for your application.
Short Across
Float Switch
Wires
A typical example of how tank and well switch signals can be used with a digital input
port is shown above in Figure 16. For a tank application, if the active wire is connected to
Position 1 and the return wire (usually black) is connected to Position G, then the Pentair
Pentek Solar Drive will stop the pump when the tank gets full because Terminals 1 and G will
be "shorted" (active short). This turns off the Pentair Pentek Solar Drive.
For a well application, if the active wire is connected to Position 2 and the return wire
(usually black) is connected to Position G, then the Pentair Pentek Solar Drive will stop
the pump when the well runs out of water because Terminals 2 and G will be "open" (active
open). This turns off the Pentair Pentek Solar Drive.
P1063 (10-03-19)
Solar Drive Sensor Settings
*
Figure 16: "Water Tank Full" and "Well Empty"
Max Frequency 55Hz
Max Frequency 60Hz
Figure 15: Maximum
Frequency Operation
Pump
Open Across
Float Switch
Wires
Well
1
2 3 4 5 6 7 8 9 10 11 12
Well
Full
Well
Empty