Important Safety Information

READ AND FOLLOW ALL SAFETY INSTRUCTIONS
FOR YOUR SAFETY: Read these instructions carefully before operating the unit.

ELECTRICAL SPECIFICATIONS

1. All wiring must comply with local and national electrical codes and must be installed by a qualifi ed electrician. If you
have any questions regarding the following instructions, contact a qualifi ed electrician.
2. Check available power supply and resolve any wiring problems BEFORE installing and operating this unit.
3. This 115V or 230/208V air conditioner uses 11.5 or less nameplate amps and may be used in any properly wired,
general purpose household receptacle. See Table 1 for specifi cations for individual branch circuit.
4. For your safety and protection, this unit is grounded through the powercord plug when plugged into a matching wall
outlet. If you are not sure whether your wall outlet is properly grounded, please consult a qualifi ed electrician.
5. The wall outlet must match the 3-prong plug on the service cord supplied with the unit. DO NOT use plug adapters.
See Table 2 for receptacle and fuse information.
6. The rating plate on the unit contains electrical and other technical data. The rating plate is located on the right side of
the unit, above the powercord.
Suggested Individual Branch Circuit
Nameplate Amps
11.5
AWG- American Wire Guage
*Based on copper wire at 105°C (221°F) temperature
Recept and Fuse Types
Model
DAC150BBCWDB / DAC150BBUWDB
Rated Volts
125
250
Amps
15
30
Wall Outlet
Fuse Size
15
20
Time Delay Fuse
(or Circuit Breaker)
TABLE 1
*AWG Wire Size
14
rating.
TABLE 2
240
15
15
Plug Type
2
Do not, under any
circumstances, cut,
remove, or bypass
the grounding prong.