INSTALLATION INSTRUCTIONS
Install Support Bracket:
5
1. Hold each support bracket fl ush against outside of sill, and tighten to bottom of cabinet as shown. in Fig. J ¹.
Mark brackets at top level of sill, and remove.
2. Assemble sill anchor bracket to outside support legs at the market position, as seen in Fig. J ² . Hand tighten,
but allow for any changes later. NOTE: Check that air conditioner is tilted downwards to the outside, about
3 ° to 4°, as shown in Fig. I. After installation, condensed water should not drain from the overfl ow drain hole
during normal use. If you notice water leaking out, check the angle of tilt, and make any necessary adjust-
ments. However, on a very humid day, water leakage can occur- this is normal. Measure the tilt angle from
the cabinet's edge . The distance H should be approximately 1 1/4" to 1 5/8".
3. Install support brackets (with sill anchor brackets attached) to correct hole in bottom of cabinet as shown in
Fig. K.
4. Tighten all 6 bolts securely.
Window Sash
Measure
the tilt
angle from
the cabinet's
edge.
Side Louvers
Sill Angle Bracket
Window Sill
Fig. I
Extend Window FIller Panels
6
1. Carefully raise the window to expose the fi ller panel locking screws. Loosen the screws do the fi ller panels slide
easily.
2. Extend panels to fi ll the widow completely. Using two 7/16 in (12mm) locking screws and a fl at washer to tighten
the locking screws on top (Fig. L1).
3. Close the window behind the top angle.
4. Attach the top angle to the window frame using a 3/32 drill bit to drill one hole through the hole in the middle of
the top angle into the window frame, and drive one ½ HEX-HEAD locking screw through the hole in the middle
of the top angle into the window frame, see Fig. L2.
5. Extend the window fi ller panels out against the window frame.
6. Use a 1/8" drill bit to drill a starter hole through the hole in the top leg of each window fi ller panel and into the
window sash (Fig. L3). Connect with one ½" long hex head screw.
7. Attach the frame lock to the window sill using one 13/16" (20mm) screw on each side as shown in Fig. L3.
Fig.L1
H
Mark
Fig. J
1
Fig.L2
7/16"Locking
Screw
and Washer
1/2in.(12.7mm) Long
Left
Left Screws And
Locknuts
Locknut
Sill Anchor
Bracket
Flat Head
Bolt
2 Each Required For
Each Support Bracket
Fig. J
2
Fig. L3
1.
1/ 2 long
HEX-HEAD
SCREW
16
Right
Fig. K
Fig.15B
1/2in. (13mm) long
Hex-head screw
(2)
13/16in. (20mm) Screw & Frame Lock (2)