Technical Specifications
EN
Voltage
Weight
Height
Length
Width
Recommended Drive Rate
Fastener Capacity
Fastener Range
Collation Range
Indicator Light
Recharge Time
Noise/Vibration Information
Measured per EN60745-1: 2009 + A11: 2020 and EN60745-2-16: 2010
Sound power level (uncertainty K=3dBa)
Sound pressure level (uncertainty K=3dBa)
Total vibration level (emission ah)
Total vibration level (uncertainty K)
Notes: The delcared vibration total has been measured in accordance with a standard test method and may be used for comparing one tool
with another.
The declared vibration total value may also be used in a preliminary assessment of exposure.
Warning: The vibration emission during actual use of the power tool can differ from declared total value depending on the ways in which
the tool is used.
Safety measures to protect the operator should be identified that are based on an estimation of exposure in the actual conditions of use
(taking account of all parts of the operating cycle such as the times when the tool is switched off and when it is running idle in addition to
the trigger time).
Troubleshooting
Problem/Symptom
Pressing mode switch does not result in
green light.
Red light on.
34 Degree
18 volts Li-ion - 3 Ahr
4.5 kg (without battery)
36,6 cm
35,6 cm
14 cm
500/Hr
Single Strip (40 Fastenrs)
50 mm - 90 mm
34 Degree
Battery condition, tool temperature, maintenance, jam
1 hour max., 30 minutes at 75% capacity
Probable Cause
Check battery.
PCB is not energized.
Electronic components damaged.
Low battery.
Maintenance required.
16
Lw = 96.0 dB(A)
Lp = 85.0 dB(A)
ah = 9.2 m/s
2
1.5 m/s
2
Corrective Action
Remove and reattach.
Pull trigger once to energize board.
Then choose mode selector.
Return to an authorized service center.
Recharge or replace battery.
Check battery connection at tool.
Is tool power good? If tool power seems
low, return to service center for pressure
check