DESCRIPTION:
1. DMX INPUT: used for DMX512 linking. Use good quality 3pin XLR M/F balanced cable to link the units
together.
2. MAINS INPUT: Use the Power cable included to connect the LDP-POWERBAR to the mains.
3. 3IN1 RGB LEDS
4. TEMPERED GLASS: protection for the LEDs
5. DISPLAY & BUTTONS
MENU
To select the programming functions
DOWN
To go backward in the selected functions
UP
To go forward in the selected functions
ENTER
To confirm the selected functions
6. Hanging brackets: with 2 knobs on both sides to fasten the unit.
7. Fixing brackets: the LDP powerbar should be fixed to a flat wall, on the ground or on the ceiling using at
least two adapted screws.
8. DMX OUTPUT: used for DMX512 linking. Use good quality 3pin XLR M/F balanced cable to link the units
together.
9. MAINS OUTPUT: Connect directly the next LDP-POWERBAR using the waterproof connector. The LDP
powerbar can be daisy chained up to 12 pieces.
10. Humidity CAP: Allow the humidity of the LDP-POWERBAR going outside the machine.
OVERHEAD RIGGING
 Important: The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials
should be used, the installed device should be inspected regularly for safety.
 Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.
 Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed at least 50cm from surrounding walls.
 The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.
 Before rigging make sure that the installation area can hold a minimum point load of 10times the device's
weight.
 Always use a certified safety cable that can hold 12times the weight of the device when installing the unit.
This secondary safety attachment should be installed in a way that no part of the installation can drop
more than 20cm if the main attachment fails.
 The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!
 Don't cover any ventilation openings as this may result in overheating.
 The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.
BRITEQ
®
OPERATION MANUAL
LDP-POWERBAR 6/12TC
ENGLISH
ELECTRICAL INSTALLATION + ADDRESSING
Important: The electrical installation should be carried out by qualified personal only,
according to the regulations for electrical and mechanical safety in your country.
Master / Slave mode:
Please refer below to the "show mode" paragraph to setup the LDP-POWERBAR.
Electrical installation for two or more units in DMX-mode:
 The DMX-protocol is a widely used high speed signal to control intelligent light equipment. You need to
"daisy chain" your DMX controller and all the connected units with a balanced cable of good quality.
 Both XLR-3pin and XLR-5pin connectors are used, however XLR-3pin is more popular because these
cables are compatible with balanced audio cables.
 Pin layout XLR-3pin: Pin1 = GND ~ Pin2 = Negative signal (-) ~ Pin3 = Positive signal (+)
 Pin layout XLR-5pin: Pin1 = GND ~ Pin2 = Negative signal (-) ~ Pin3 = Positive signal (+) ~ Pins4+5
not used.
 To prevent strange behavior of the light effects, due to interferences, you must use a
90Ω to 120Ω terminator at the end of the chain. Never use Y-splitter cables, this
simply won't work!
 Make sure that all units are connected to the mains.
 Each light effect in the chain needs to have its proper starting address so it knows
which commands from the controller it has to decode. In the next section you will learn how to set the DMX
addresses.
DMX mode:
OPERATING INSTRUCTIONS
 Once connected to the mains, the device starts running.
 Always unplug the unit when it is not used for a long time or before to start servicing.
 In the event of serious operating problems, stop using the fixture and contact your dealer immediately.
 Important: Never look directly into the light source! Don't use the effect in the presence of persons
suffering from epilepsy.
MAIN MENU:
 To select any of the functions, press the MENU button up to when the required one is shown on the
display or use the DOWN and UP buttons to browse the menu.
 Select the function with the ENTER button (the display blinks).
 Use DOWN and UP buttons to change the mode.
 Once the required mode is selected, press the ENTER button to confirm.
To go back to the main menu without any change press the MENU button shortly. The main menu is shown
in the chart.
DMX512 Address Setting
Used to set the starting address in a DMX setup.
 Press the MENU button until
is shown on the display.
 Press the ENTER button, the display starts blinking.