11) HOW TO ADJUST THE MECHANICAL STOPPERS (FIG.11)
After the motor stop, the inertial movement of the beam is blocked thanks to adjustable mechanical stoppers.
By taking Fig.11 as a reference:
• Loosen locking screws V1 and V2.
• Tighten/loosen the mechanical stoppers F1 and F2 until the desired activation position is obtained.
• Fix screws V1 and V2.
12) WIRE DIAGRAM (FIG.12)
This figure shows an installation example of road barrier with its main accessories.
KEY
1. Control unit CP.EVA2
2. Receiver photocell FTC.S
3. Transmitter photocell FTC.S
4. Emergency batteries that can be installed inside the container of the control unit DA.BT2
5. EVA.LAMP flashing light card
6. Safety edge resistive type (8K2)
7. Control unit for safety edge management SC.EN
To install and connect the various accessories, see related instructions.

13) CP.EVA2 CONTROL UNIT

13.1) WIRE DIAGRAM

Wire connections shown in Fig. 13 are described hereunder:
TERMINALS
Function
ANT-SHIELD
Antenna
AUX
Auxiliary output AUX 1
24V
24 Vdc
MOT
Motor
P.P.
Step by step
CLOSE
Close
OPEN
Open
PHOT
Photocell
STOP
STOP
SWC
Closing limit switch
SWO
Opening limit switch
COM
Common
AUX2
24Vdc output for bar light
BLINK
Blinker
ABS ENC
Encoder input
M1
24Vdc INPUT

13.2) PROGRAMMING

The programming of the various functions of the control unit is carried out using the LCD display on the control unit and setting the desired values in
the programming menus described below.
The parameters menu allows you to assign a numerical value to a function, in the same way as a regulating trimmer.
The logic menu allows you to activate or deactivate a function, in the same way as setting a dip-switch.

13.2.1) TO ACCESS PROGRAMMING

1 -Press the <PG> button to enter the first Installation menu "INST".
2 -Choose with <+> or <-> button the menu you want to select (see menu at page 10-11)
3 - Press the button <PG>, the display shows the first function available on the menu.
4 - With the <+> or <-> button, select the function you want.
5 - Press the button <PG>, the display shows the value currently set for the function selected.
6 - With the <+> or <-> button, select the value you intend to assign to the function.
7 - Press the button <PG>, the display shows the signal "PRG" which indicates that programming has been completed.
24
TERMINAL BLOCK 1
Description
Connection for the antenna of the built in receiver (ANT-signal/SHIELD-shield).
In case of use of an external antenna it is necessary to remove the pre-cabled cable from the terminal ANT
Output with N.O. contact configurable by means of the logic AUX 1
Accessory power supply 24Vdc 500 mA maximum
Motor connection: 24Vdc.
TERMINAL BLOCK 2
Input for step by step command (N.O. contact) .
Input for close command (N.O. contact) .
Input for open command (N.O. contact), It is possible to connect a timer for programmed openings.
Input for photocells enabled during opening and closing phase (N.C. contact).
Input for STOP command (N.C. contact).
Input for closing limit switch (N.C. contact).
To be used ONLY FOR BARRIER WITH ELECTROMECHANICAL LIMIT SWITCHES. If not used it is NOT
NECESSARY TO BRIDGE the input to the common COM.
Input for opening limit switch (N.C. contact).
To be used ONLY FOR BARRIER WITH ELECTROMECHANICAL LIMIT SWITCHES. If not used it is NOT
NECESSARY TO BRIDGE the input to the common COM.
Common for all the input commands and the limit switches .
24Vdc output for the bar flashing light (EVA.L) the flashing mode can be set by means of the logic LBAR.
Output 24Vdc 15W max. for flashing light connection (EVA.LAMP) to be installed on the top cover of the barrier.
TERMINAL BLOCK 3
Absolute encoder input, pre-cabled by factory.
TERMINAL BLOCK M1
24Vdc input for powering the CP.EVA2.In case of use of the SUN SYSTEM it is necessary to connect
the 24Vdc output of the SUN.SY to M1 (see the KSUN instructions)