6.2
Commissioning the product
INCORRECT PRESSURE IN INTERSTITIAL SPACE
•
Verify that the pressure in the interstitial space of the tank corresponds to the
specifications.
Failure to follow these instructions can result in equipment damage.
Verify that the product has been properly mounted and electrically con-
nected.
Verify that the information on the nameplate of the tank has been
accounted for.
Verify that the correct number of drying filters is correct.
Verify that the tightness test has been performed.
Verify that the interstitial space has been pressurised.
1. Apply voltage via the on-site mains fuse.
- The green LED is on.
- The pump controller keeps the pressure constant. Once the target pres-
sure is reached, the pump switches off.
- The system is now ready for operation.
2. Perform a function test.
The specialised company certifies the installation, commissioning and test of
the product (see "Certificate of expert").
Commissioning
NOTICE
Europress
EN
37