4.6
Approvals, conformities, certifications
The product complies with:
•
EMC Directive (2014/30/EU)
•
Low Voltage Directive (2014/35/EU)
•
Construction Products Directive (EU) No. 305/2011 and No. 574/2014
•
RoHS Directive (2011/65/EU)
4.7
Technical data
Parameter
General specifications
Weight
Emission/alarm sound
Additional connections
Breaking capacity output relay
Relay fuse
Operating pressure in interstitial
space
Switching point Alarm On
Switching point Alarm Off
Switching point Pump On
Switching point Pump Off
Safety valve opens
Hose line standard
Length of hose line
Product description
Value
1.2 kg
Min. 70 dB(A)
A-weighted sound level of the audible
alarm at a distance of one metre
1 output relay (changeover contact)
Max. 250 V, 2 A, resistive load
T 2 A
Approx. 510 mbar
470 ±10 mbar
500 ±10 mbar
500 ±10 mbar
530 ± 0 mbar
≥ 570 mbar
PVC hose 6 x 2 mm
Max. 50 m
Standard version
Special version
See nameplate on
product.
Europress
EN
15