installation (continued)
5
Attaching the mounting bracket to the
electrical box
□
Position the wires back inside the electrical box.
□
Mount the mounting bracket (AA) to the electrical box using
the two electrical box screws (DD).
6
Attaching the housing to the ceiling
□
Drill a 1/8-in. pilot hole into each of the screw locations marked on the ceiling. You can also use an awl or
nail to dimple the screw holes.
□
Install a drywall anchor (EE) and a mounting screw (FF) in each drilled mounting hole, but do not tighten
fully.
□
Align the 2 mounting keyholes on the fixture housing (A) with the 2 mounting screws (FF) in the ceiling.
Once the screw heads are through the large ends of the keyholes, slide the housing (A) until the heads of
the mounting screws (FF) slide into the narrow ends of the keyholes.
□
Finish tightening the mounting screws (FF) until the fixture housing (A) is tightly secured to the mounting
surface.
nOTe: The drywall anchors
(EE) are only to be used for
mounting the fixture to plaster
or drywall surfaces.
EE
Wire
connectors
DD
AA
A
FF
6
installation (continued)
7
Attaching the diffuser to the housing
CC
□
Insert one end of the diffuser (B) into the end cap of the
housing (A) to the bottom of the limit part.
□
Push the other end of the diffuser (B) to the top of the
limit part on the opposite end cap.
□
Restore power to the electrical box.
□
Turn on the light switch to activate the fixture.
AA
Care and Cleaning
CaUTiOn: Before attempting to clean the fixture, disconnect the power to the fixture by turning the breaker off or removing the fuse from
the fuse box.
□
Clean the fixture with a soft, dry cloth.
□
Do not use cleaners with chemicals, solvents, or harsh abrasives.
□
Do not use liquid cleaner on the LEDs, LED driver, or wiring inside the light fixture.
Troubleshooting
WarninG: Before doing any work on the fixture, disconnect power to the light fixture.
Minor problems often can be fixed without the help of an electrician.
Problem
The fixture will not light.
The fuse blows or the
circuit breaker trips when
the light is turned on.
B
Possible Cause
The power is off.
Ensure the power supply is on.
The circuit breaker is off.
Ensure the circuit breaker is in the on position.
There is a bad connection.
Check to ensure proper wire connections are made.
Contact a qualified electrician.
There is a defective switch.
Contact a qualified electrician.
The wires are crossed or the
Check the wire connections.
power wire is grounding out.
Contact a qualified electrician or call customer
service 1-855-384-7754.