NOTE: Keep your receipt and these instructions for proof of purchase.
WARNING: Shut off the power at the circuit breaker or fuse panel before removing the old fixture, ballast, or fluorescent
tubes.
If you are unfamiliar with electrical installations, we recommend you contact a qualified electrician to do the installation.
INSTALLATION
Part # DL-3-45-902-SV-D / Model # 53809111 can be installed into 3 1/4" and 3 3/4" housings.
Part # DL-4-65-902-SV-D / Model # 53808211 can be installed into 4 1/4" and 4 3/4" housings.
Part # DL-5-90-902-SV-D / Model # 53807211 can be installed into 5 1/8" and 5 3/4" housings.
1
Shut off power at the electrical panel before beginning the installation.
2
If installing the fixture in a preexisting hole: Remove existing can and fixture and set aside to recycle in accordance
with local requirements. Measure the ceiling hole to make sure it is the correct size for the fixture.
3
If installing the fixture in a new location: Trace the hole template in the desired ceiling location and use a hole saw
to cut out the hole.
NOTE: 1/2" or 5/8" drywall recommended for easy installation.
4
Choose your favorite correlated color temperature (CCT) before installing the fixture.
NOTICE: The factory setting for the correlated color temperature (CCT) is 2700K, which is the warmest white light.
Open electrical box cover.
5
D
Make the electrical connections:
8
• Black wire to black wire.
• White wire to white wire.
Use wire connectors* to cover the wire
connections and wrap with electrical tape.
Tuck wires inside the electrical box.
Close the electrical box cover.
WARNING: Carefully read and understand the information given in this manual before beginning the assembly and installation. Failure to do so could lead to electric shock, fire, or
other injuries which could be hazardous or even fatal. • Ensure the electricity to the wires you are working on is shut off. Either remove the fuse or turn off the circuit breaker. • Risk
of fire or electric shock. Installation of this LED Downlight requires a person familiar with the construction and operation of the light fixture's/luminaire's electrical system and the
hazard involved. If not qualified, do not attempt installation. Contact a qualified electrician. • Do not make or alter any open holes in an enclosure of wiring or electrical components
during kit installation. • To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
NOTICE: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio
or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna, increase the separation between the equipment and the receiver, connect the equipment into an outlet on a circuit different from that to which
the receiver is connected, and consult the dealer or an experienced radio/TV.
• Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. • Not for emergency lighting.
See website for Warranty, Troubleshooting or Care and Cleaning details at www.ETiSSL.com.
USE AND CARE GUIDE
Punch out 1 of the knock out holes.
6
Insert the electrical box into the opening in the ceiling.
9
Connect the connector cable from the electrical box to the
connector cable from the fixture.
NOTE: The electrical box must be no more than 22in.
from fixture based on the length of the connector cables.
Questions, problems, missing parts? Call ETiSSL Customer Service 8 a.m. - 5 p.m., CST, Monday - Friday
1-855-ETI-SSLI (1-855-384-7754) www.ETiSSL.com
Part # DL-3-45-902-SV-D, DL-4-65-902-SV-D, DL-5-90-902-SV-D
Certification # 53809111, 53808211, 53807211
PACKAGE CONTENTS
Part
A
B
C
D
Knock
Out Hole
Model # 53809111, 53808211, 53807211
®
Description
Quantity
Fixture
1
Electrical Box
1
Hole Template
1
Wire Nuts
2
A
Run wires per local electrical code and feed
7
wires through the knock out hole.
Compress the spring clips and insert the fixture
10
into the opening in the ceiling.
Restore power at the electrical panel.
Turn on the light switch to activate the fixture.
B
D
C

Publicité

loading

Sommaire des Matières pour ETI 53809111

  • Page 1 Electrical Box INSTALLATION Hole Template Part # DL-3-45-902-SV-D / Model # 53809111 can be installed into 3 1/4” and 3 3/4” housings. Wire Nuts Part # DL-4-65-902-SV-D / Model # 53808211 can be installed into 4 1/4” and 4 3/4” housings.
  • Page 2 Serre-fils Le n° de pièce DL-3-45-902-SV-D / N° de modèle 53809111 peut être installé dans un boîtier de 8,3 ou 9,5 cm. Le n° de pièce DL-4-65-902-SV-D / N° de modèle 53808211 peut être installé dans un boîtier de 10,8 ou 12 cm.
  • Page 3 Las informaciones sobre la garantía, la solución de problemas, el mantenimiento y la limpieza se puede encontrar en el sitio web: www.ETiSSL.com. Preguntas, problemas, piezas faltantes? Llame al Centro de Atención al Cliente de ETi en el horario de 8 a.m. - 5 p.m., HSC, de lunes a viernes.

Ce manuel est également adapté pour:

5380821153807211Dl-3-45-902-sv-dDl-4-65-902-sv-dDl-5-90-902-sv-d