INSTALLATION
This light fixture is suitable for wall mounting or eave mounting only. It is not suitable for ground
mounting installation. The light fixture should be mounted a minimum of 6.5 ft. (2.0 m) above the
ground. If two walls intersect, than the distance between the intersecting line and the light fixture
should be more than 2 ft. (0.6 m).
Shut off power at the electrical panel before beginning the installation.
1
Remove existing fixture and set aside to recycle in accordance with local requirements.
2
Choose your favorite correlated color temperature (CCT) before installing the fixture.
3
NOTICE: The factory setting for the correlated color temperature (CCT) is 3000K, which is the
warmest white light.
Choose the desired brightness (lumen output).
4
NOTICE: The factory setting for the brightness (lumen output) is 2400lm.
Use the 2 short mounting screws to attach the mounting bracket to the
5
electrical box.
Make sure the text "GND" faces out.
Green
F
Black(L)
D
White(N)
Make the electrical connections:
7
• Black wire to black wire.
• White wire to white wire.
• Ground wire to ground.
• Connect the ground wires to the grounding screw
on the mounting bracket.
Use wire connectors to cover the wire connections
and wrap with electrical tape.
Adjust the light heads to the desired
11
position.
NOTE: If mounted with the photocell sensor
in the down position, the angle between the light
head and the wall should be larger than 45° for best performance.
NOTE: As an option, the light fixture can be installed with the photocell sensor
positioned at the top of the security light.
USE AND CARE GUIDE
G
C
B
Use the long mounting screw to attach the
8
fixture to the mounting bracket.
Make sure no wires are visible.
Insert the rubber plug into the hole on the
fixture.
THIS SIDE UP
Part # SC-2HD-2400LM-8-CP3-SV-OS-BZ, SC-2HD-2400LM-8-CP3-SV-OS-W
PACKAGE CONTENTS
Part Description
A
Fixture
B
Mounting Screw (long)
C
Mounting Screw (short)
D
Grounding Screw (green)
E
Rubber Plug
F
Wire Connector
G
Mounting Bracket
H
Foam Gasket
H
G
Place the foam gasket on the electrical box.
6
Pull the wires from the electrical box through the opening in the foam gasket.
E
Testing the Photocell Motion Sensor:
12
• Turn the timer knob to Test.
• Move in front of the sensor and the light will turn on and then off
after 5 seconds.
Model # 51406111, 51406112
Certification # 51406111, 51406112
Quantity
1
1
2
A
1
1
D
E
3
1
G
1
Apply silicone sealant (not included) to
9
the edges of the fixture.
10
Use the Color Preference
switch to
®
select the desired color temperature.
B
C
F
H
H
G