Mount To 4 In. Housing; Adjusting The Light Output; Care & Cleaning; Troubleshooting - ETI DL-6-11-907-SV-D Guide D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Mount to 4 in. Housing (continued)
3
Connecting the cables
Plug the cable connector on the socket
adapter (B) into the connector on the LED light
module (A).
B
A

adjusting the light output

This downlight allows you to customize the color temperature and brightness (lumen output) of the light.
Choose your favorite correlated color temperature (CCT) from five options: 2700K, 3000K, 3500K, 4000K, or
5000K.
noTe: The factory setting for the correlated color temperature (CCT) is 2700K, which is the warmest white light.
Choose the desired brightness (lumen output) from three options: 700 lm, 900 lm, or 1100 lm for
Ordering # 53801102 and 600 lm, 800 lm, or 1000 lm for Ordering # 53802102.
noTe: The factory setting for the brightness (lumen output) is 1100 lm on Ordering # 53801102 and 1000 lm on Ordering # 53802102.
Move the toggle switch on the side of the LED light module to make your selections before pushing the LED
light module into the recessed can housing.
Ordering # 53801102
1100 lm
900 lm
700 lm
4
Pushing the LEd light module
into the recessed can housing
Carefully push the LED light module (A) into
the recessed can housing until the trim is flush
with the ceiling surface.
noTiCe: Select the preferred color temperature and
brightness before pushing the LED light module (A) into
the recessed can housing.
A
Ordering # 53802102
2700K
3000K
3500K
4000K
5000K
8
Care & Cleaning
CaUTion: Before attempting to clean the fixture, disconnect the power to the fixture by turning the breaker off or removing the fuse from
the fuse box.
Clean the fixture with a soft, dry cloth.
Do not use cleaners with chemicals, solvents, or harsh abrasives.

Troubleshooting

WarninG: Before doing any work on the fixture, disconnect power to the light fixture by turning the breaker off or removing the fuse from
the fuse box.
Minor problems often can be fixed without the help of an electrician.
Problem
The fixture will not light.
The fuse blows or the
circuit breaker trips when
the light is turned on.

light distribution

Ordering # 53801102
2700K
3000K
3500K
4000K
5000K
1000 lm
800 lm
600 lm
Possible Cause
The power is off.
Ensure the power supply is on.
The circuit breaker is off.
Ensure the circuit breaker is in the on position.
There is a bad connection.
Check to ensure proper wire connections are
made. Contact a qualified electrician.
There is a defective switch.
Contact a qualified electrician.
The wires are crossed or the
Check the wire connections.
power wire is grounding out.
Contact a qualified electrician or call ETi customer
service at 1-855-384-7754.
100
200
300
C0/180, 100.2
400
C30/210, 100.1
C60/240, 100.1
500
C90/270, 100.0
9
Please contact 1-855-384-7754 for further assistance.
Corrective Action
Ordering # 53802102
110
220
330
C0/180, 94.5
440
C30/210, 94.5
C60/240, 94.5
550
C90/240, 94.5
www.ETiSSL.com