Télécharger Imprimer la page

CAME BPT TA/600 Manuel D'installation Et D'utilisation page 38

Thermostat écran tactile

Publicité

Les langues disponibles

Les langues disponibles

O
Cycle duration
Minimum ON
Prog.
(minutes)
time (minutes)
10
1
P1
5
1
P2
20
2
P3
from 5 to 40 from 1 to 5
P4
A
B
ON
1 h
Proportional
Range
1.5 °C
1.5 °C
1.5 °C
from 1 °C to 3 °C
button in figure N to be able to enter
Press the
ON
the value of the proportional band, using the
arrows O.
Press the
button to move on to the next parameter
to be configured.
Set-point
Type of system
Base for gas burner, convector heaters, zone valves,
aluminium radiators
Electric radiators
Radiant or underfloor systems, cooling
Setting the unit of measurement for the temperature
Choose the unit of measurement for the temperature
arrows A.
using the
Press the
button to move on to the next parameter
to be configured.
Screen backlighting
arrows B, choose whether the back-
Using the
lighting should always be on (ON) or only when the
display is touched (OFF).
Press the
button to move on to the next parameter
to be configured.
Time