Moteur hydraulique geroler avec soupape à disque à 2 boulons de 19,0 po cubes

Publicité

Les langues disponibles

Les langues disponibles

19.0 cu. in. 2-Bolt Hydraulic disc Valve Geroler Motor
V 3.03
11. Lubricate O-rings (24, 25) and
insert them into the channel
plate (23). Insert the pin (26)
into the channel plate (23), and
attach the assembled channel
plate (23) to the end plate
(29). Ensure that all parts are
properly aligned.
12. Connect the assembled
channel plate (23) and end
plate (29) to the distributor
plate (22).
13. Attach the end plate (29) to
the assembly using the screws
(33) and washers (32).
14. Insert the washer (13) into its
groove and tighten the drain
plug (14).
15. Put the dust seal (1) into the
housing (2), and insert the
woodruff key (5) into the output shaft (4).
INSTALLATION
The hydraulic motor is only one component of the hydraulic circuit.
Place the motor downstream from the control mechanism, such
as a variable flow valve spool. Check that the pressure hoses
connecting the motor to the hydraulic circuit can withstand the
circuit's maximum pressure.
1. Place the gerolor motor into position and bolt it onto a
frame or appliance. Check that the output shaft is properly
connected to the appliance or the prime mover before
tightening the bolts.
2. Ensure that the motor is full of oil prior to attaching
the hoses.
3. Connect a hydraulic pressure hose from the directional
control valve to the motor's inlet port.
14
For technical questions call 1-800-665-8685
8490690