12 Ordering codes
6.924.X10X.XXC
2 additional relay outputs
Input trigger levels
Supply voltage
LCD version
Outputs
Front
13 Frequencies (typical)
13.1
Pulse counter
HTL level
AC supply
DC supply 12V
DC supply 24V
Add
Sub
55 kHz
Cnt.Dir
Up.Dn
20 kHz
Up.Up
Quad
28 kHz
Quad 2
10 kHz
Quad 4
A/B
(A-B)/A
R60320.000 – Index 5
0 = Standard (HTL)
A = Fixed level*
0 = 100... 240 V AC ± 10%
3 = 10 ... 30 VDC
0 = no backlighting
1 = green backlighting
2 = LED Look
3 = Multicolour
0 = Relays
0 = Kübler version
A = Neutral version
*Fixed level (Low 0 ... 2 V DC,
High 3,5 ... 30 V DC)
typ. Low
2.5 V
typ. High
22 V
typ. Low
2 V
typ. High
10 V
typ. Low
2.5 V
typ. High
22 V
AddAr
AddTot
SubAr
AddBat
1.5 kHz
1.6 kHz
1.5 kHz
1.6 kHz
0.7 kHz
0.7 kHz
0.7 kHz
0.7 kHz
29 kHz
5V level
typ. Low
1.0 V
typ. High
4.0 V
Add
Sub
9 kHz
Cnt.Dir
Up.Dn
9 kHz
Up.Up
Quad
9 kHz
Quad 2
9 kHz
Quad 4
A/B
(A-B)/A
13.2
Frequency meter
HTL level
AC supply
DC supply 12V
DC supply 24V
5V level
HTL
65 kHz
A
A – B
A + B
59 kHz
A / B
(A-B)/A
30 kHz
Quad
NOTE: Switching levels of the input
Switching levels with AC supply:
HTL level
Low:
High:
5V level
Low:
High:
Switching levels with DC supply:
HTL level
Low:
High:
5V level
Low:
High:
AddAr
AddTot
SubAr
AddBat
1.3 kHz
1.6 kHz
1.3 kHz
1.6 kHz
0.5 kHz
0.7 kHz
0.5 kHz
0.7 kHz
9 kHz
typ. Low
2.5 V
typ. High
22 V
typ. Low
2 V
typ. High
10 V
typ. Low
2.5 V
typ. High
22 V
typ. Low
1,0 V
typ. High
4,0 V
5V
9 kHz
9 kHz
9 kHz
0 ... 4 VDC
12 ... 30 VDC
0 ... 2 VDC
3.5 ... 30 VDC
0 ... 0,2 x U
B
0.6 x U
... 30 VDC
B
0 ... 2 VDC
3.5 ... 30 VDC
EN - page 20