Count mode ADDING with
automatic reset and Total
counter
Output 2 (timed signal) active
when main counter = preset
value 2
Automatic reset to zero when
main counter = preset value 2
Output 3 active when main
counter > preset value 3
Total counter counts all the count
pulses from the main counter
Output 1 resp. 4 active when
total counter > preset value 1
resp. 4
Manual Reset sets both counters
to zero
Electronic reset only sets the
main counter to zero
7.8.6.3 Mainmenu for configuration
Mainmenu for matching the time
ranges and display
Unit of time
Unit of time: seconds
Decimal point setting determines
the resolution
Unit of time: minutes
Decimal point setting determines
the resolution
Unit of time: hours
Decimal point setting determines
the resolution
Unit of time: Hrs. Min. Sec.
Decimal point setting (Resolution)
Decimal place
(determines the resolution)
0
0.0
0.00
0.000
Set value
Set value can be programmed
from 000000 to 999999
A previously programmed
decimal point will be displayed
R60320.000 – Index 5
no decimal place
1 decimal place
2 decimal places
3 decimal places
Display colour (for device 6.924.x103.xxC]
Display colour
upper line
lower line
Display colour
upper line
lower line
7.8.6.4 Mainmenu for reset mode
Setting the reset mode
Manual reset (with red key) and
electrical reset (reset input)
No reset possible (red key and
reset input inhibited)
Only electrical reset possible
(reset input)
Only manual reset possible (red
key)
7.8.6.5 Mainmenu for Preset 1
Mainmenu for turning preset 1
ON/OFF
ADD mode output operations:
permanent signal at Output 1,
becomes active when count >
Preset 1
SUB mode output operations:
permanent signal at Output 1,
becomes active when count <
Preset 1
ADD mode output operations:
permanent signal at Output 1,
becomes passive when count >
Preset 1
SUB mode output operations:
permanent signal at Output 1,
becomes passive when count <
Preset 1
red
red
red
green