Terminal Assignment; Delivery Includes; Ordering Code; Technical Data - Kübler 521 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5. Terminal assignment

5.1 Without optocoupler output
1
10-30 VDC
2
0 V (GND)
3
INP A
4
INP B
5
SET
5.2 With optocoupler output (npn)
1
10-30 VDC
2
0 V (GND)
3
INP A
4
INP B
5
SET
6
Emitter
7
Collector

6. Delivery includes:

- CODIX 521
- Panel mounting clip
- Bezel for screw mount, panel cut-out 50x25 mm
- Bezel for clip mount, panel cut-out 50x25 mm
- Sealing

7. Ordering code:

6.521.01X.300
Output
1 = Opto coupler
2 = no output

8. Technical data

Supply voltage:
10...30 VDC, max. 50 mA
Display:
6digit LED-Display, 8 mm character height
Polarity of input signals:
programmable for inputs in common (npn or pnp)
Input resitance: appr. 10 k
Count frequency: 20 kHz can be damped to
30 Hz (max. 11 kHz when using quadrature mode)
Min. pulse length of the reset input: 5 ms
Input sensitivity:
log. „0": 0 VDC..0,2xU
log. „1": 0,6 x U
Pulse shape: variable (Schmitt Trigger
characteristic)
Max. switching performance of the
optocoupler: 30 V at 10 mA
Data retention:
via EEPROM 1x10
6
memory cycles or 10 years
Noise immunity:
EN 50081-2; EN 55011 class B; EN 50082-2
Ambient temperature: -10 °C...+50 °C
Storage temperature: -25 °C...+70 °C
Weight: appr. 50 g
Protection: IP 65 (front)
Cleaning:
The front of the unit is only to be cleaned with a
soft wet (water !) cloth.
W
B
..30 VDC
B
15

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

522523524

Table des Matières