4.3 Device shutdown

To turn off the device, simultaneously press and turn the knob all the way clockwise (
will be cut and the flame on burner will be turned off.
Additionally, close also the valve on the gas cylinder.
4.4.

Replacing the battery

If the battery is inserted incorrectly, the electronic ignitor may be irreparably damaged. Only replace the battery when
the appliance has been completely switched off.
The battery is placed in the container located on the control panel next to the flame regulation knob.
Unscrew the ignition button
Remove the battery and place the new one into the container.
WARNING!
Remember about proper polarization of the battery.
Screw the cover of the battery container.

5. TESTING

WARNING!!!
NEVER TURN ON THE DEVICE IF THE CHARACTERISTIC SMELL OF GAS IS PERCEPTIBLE.
In the event of gas leakage, the appliance shall not be used or if alight, the gas supply shall be shut off and the appliance
shall be investigated and rectified before it is used again. If you smell gas during the operation of the fireplace turn off
the device immediately and cut off the gas supply from the gas cylinder by shutting its valve.
Fig 14 – Turning off the device
Fig 15 – Replacing the battery
15
14). The gas supply