Open the valve on gas cylinder.
•
Press the knob and while still pressing turn it counter-clockwise from position (1) to position (2)
•
While keeping the knob still pressed start the flame by pressing the ignition button (3).
•
A spark will appear which ignites the main burner on the minimum flame height. If the flame did not ignite
repeat this process 2-3 times. This will be required especially when you have replaced and installed a new LPG
gas cylinder.
•
When the flame is ignited keep holding the knob for around 5 seconds until the thermo-couple, which will
keep the main valve in an open position, warms up.
•
You may now release the knob. If however the flame is extinguished repeat the process once again until a
stable flame is achieved.
WARNING!!!
After 2-3 unsuccessful attempts terminate and check the connections. Try again in 10 minutes. If the
installed gas bottle is new or the fireplace has not been used for a longer period the first thing that needs to be done
is to release air from the gas linkage. In this case conducting a few attempts will be needed until the flame is ignited.
4.2 Regulation of the flame size
•
When the flame is burning the desired height of the flame may be adjusted and regulated by turning the knob
clockwise or counter-clockwise.
•
To achieve a higher flame turn the knob counter-clockwise to "Hi" position. To achieve a lower flame turn the
knob clockwise to "Lo" position (
Fig 11 – Turning on the device
Fig 12 – Pressing the on button
).
Fig 13
Fig 13 – Adjusting the flame high
14