Floor nozzle
Suited for all washable wall and floor cover-
ings, e.g. stone floors, tiles and PVC floors.
Work slowly on very dirty surfaces to allow
the steam to act on the dirt for a longer pe-
riod of time.
Note:Detergent residue or care emulsions
that are still present on the surfaces to be
cleaned, can lead to smears when steam
cleaned. However, these will disappear
with repeated cleaning procedures.
 Illustration
Attach the floor cloth to the floor nozzle.
1 Fold the floor cloth the long way and
place the floor nozzle on top of it.
2 Open holding clamps.
3 Place the cloth ends into the openings.
4 Close the holding clamps.
Caution
Do not insert fingers between the clamps.
Parking the floor nozzle
 Illustration
During work breaks, hook the floor noz-
zle into the parking holder.

Maintenance and care

Danger
Always disconnect the mains plug and al-
low the steam cleaner to cool down before
performing any maintenance work.
Rinsing the steam boiler
Rinse the steam cleaner boiler at the latest
after 10 boiler fillings.
 Disconnect the mains plug from the
socket.
 Allow the steam cleaner to cool down.
 Empty the water reservoir.
 Remove the accessories from the ac-
cessory compartments.
Illustration
 Open the maintenance lock. For this,
place the open end of an extension pipe
onto the maintenance lock, lock it into
the guide and unscrew it.
 Fill the boiler with water and shake it
strongly. This dissolves lime scaling re-
18
siding on the boiler bottom.
 Completely empty the steam boiler to
remove existing water (see Fig.
Descaling the Steam Boiler
As limescale builds up on the boiler walls,
we recommend to descale the boiler in the
following intervals (RF=reservoir fillings):
Degree of hard-
ness
I
soft
II medium
III hard
IV very hard
Note: Please contact your Conservancy
Board or the local water supply company to
inquire about the hardness of your water.
 Disconnect the mains plug from the
socket.
 Allow the steam cleaner to cool down.
 Empty the water reservoir.
 Remove the accessories from the ac-
cessory compartments.
Illustration
 Open the maintenance lock. For this,
place the open end of an extension pipe
onto the maintenance lock, lock it into
the guide and unscrew it.
 Completely empty the steam boiler to
remove existing water (see Fig.
Warning
Only use products approved by KÄRCHER
to exclude any damages of the appliance.
 User the KÄRCHER decalcifier sticks
(order no. 6.295-047) to decalcify the
water. Please follow the dosing instruc-
tions on the packaging while using the
decalcifying solution.
Caution
Use caution when filling and emptying the
steam cleaner. The descaling solution can
have an aggressive effect on delicate sur-
faces.
 Pour the descaling solution into the boil-
er and allow it to react for approximately
8 hours.
EN
– 10
).
° dH
mmol/l
RF
0- 7
0-1,3
100
7-14
1,3-2,5
90
14-21 2,5-3,8
75
>21
>3,8
50
).