5.0 installation
installation
EN
WARNING
!
Minimum terminal and appliance clearance to combustibles must be maintained or a serious fire hazard could
result.
5.1
vinyl siding - less than 1" (25mm) (4"/7" only)
1.0 Attach the termination to the venting, see "pre-installation" and "venting"
sections.
note:
All inner flex pipe and outer flex pipe joints to the termination may be sealed
using high temperature red RTV silicone W573-0002 (not supplied) or the
high temperature sealant W573-0007 Mill Pac (not supplied). However, the
high temperature sealant W573-0007 Mill Pac (not supplied) must be used
on the joint connecting the inner flex pipe and the exhaust flue collar of the
appliance.
2.0 Install the termination and venting from the outside of the building, bringing
the venting through the opening in the wall. Secure using 4 screws
(supplied in terminal kit). The screws should penetrate the sheathing and
into the wall framing.
3.0 Apply a bead of clear silicone to seal the edges of the termination.
4.0 Apply the vinyl siding around the termination, sealing between the
termination and vinyl siding (less than 1" [25mm]) with silicone.
note:
Diagram is for illustrative purposes only. Installation must comply with all local codes.
16
W415-2899 / A / 10.07.20
Terminal
X 4
(4"/7" only)
Required (for 4"/7"):
Terminal (ST47U)