Environment Of Use; Technical Description; Specifications; List Of Components - TELLARINI POMPE EEM Manuel D'instructions Et D'entretien

Pompe auto-amorçante à canal latéral
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
- must have a maximum temperature of: models without by-pass:
depending on the rubber used to manufacture the gaskets: 90° C (NBR
rubber, which is standard unless otherwise indicated on the pump), 110° C
Examples of use of the series with brass pump body (series EEM,
ENM, ENT, ECC)
brass pumping body are generally not considered suitable for use with
food products, such as milk or olive oil (ref. standard UNI EN 13951).
Application in the food sector is subordinate to checking suitability of the
pumps with the provisions of the specific HACCP plan drawn up by the
user.
Examples of use of series with AISI 316 stainless steel pump body,
material suitable for foods and with excellent resistance to corrosion
and abrasion (series AL)
-
appropriate methods of washing and disinfecting the pump must be
- compatible corrosive liquids (such as fungicides or liquid fertilizers)
- the same liquids permitted for brass pumps, in this case ensuring a much
longer useful life.
Use of the pump in environments in which there is danger
particular, do not use with petrol, acetone, solvents, etc.
2.2 – ENVIRONMENT OF USE
- Ventilated, clean and dry closed environment.
- Normal or marine atmosphere, ambient temperature between –15 ° C
and 40 ° C and maximum relative humidity 80%.
- Maximum installation altitude: 1000 meters above sea level.
3 – TECHNICAL DESCRIPTION

3.1 - SPECIFICATIONS

The pump can perform suction of liquid from one port (suction port),
characterizing a pump is capacity Q (quantity of liquid transferred in a
The capacity of a pump is not fixed, but depends on the total manometric
head H required by the installation, which is the sum of two contributions:
TYPE
EEM 20 L, ENM 20 L, ENT 20 L
EEM 20, ENM 20, ENT 20
EEM 25, ENM 25, ENT 25
ENM 25S, ENT 25S
EEM 30, EEM 35
ENM 30, ENT 30
ENM 35, ENT 35
EEM 40
ENM 40, ENT 40
ENM 50
ENT 50
ECC 12/20
ECC 24/20
ECC 12/25
Data obtained with water at 20° C – Tolerances: standard ISO 2548 for Class C mass produced pumps
models with by-pass: 90° C.
Hmax
1 m
5 m
10 m
(bar)
12
3
0.6
28
22
15
2.2
43
29
9
1.2
4.8
88
83
77
86
67
42
1.7
86
69
45
1.7
1.7
86
69
45
125
97
64
1.5
130
100
68
1.7
2.9
230
208
170
230
208
170
2.9
25
18
10
1.5
26
20
13
1.6
1.8
55
42
22
1) difference in height (measured vertically) between the level of liquid in
2) energy losses caused by liquid flow in pipes, valves, fittings, and other
elements inserted along its path.
Tab. A indicates the capacity (in litres per minute) as a function of total
manometric head (in metres) for the various pump types. The same table
also indicates the value of the maximum head Hmax developed by the
pump (expressed in bar, unit of pressure measurement), which is reached
when the discharge port is closed, and the maximum equivalent A-
weighted sound pressure level (LeqA) obtained at 1 metre from the
surface of the pump operating with water at 20° C.
3.2 – LIST OF COMPONENTS
Tab. B contains the list of all components, and refers to Figs. 1, 2, 3A, 3B,
4, 9.
- Fig. 1: exploded drawing of single-phase electric pumps type ENM 20,
ENM 20 L, ALM 20, ALM 20 L, EEM 20, EEM 20 L and three-phase
electric pumps type ENT 20, ENT 20 L, ALT 20 e ALT 20 L.
- Fig. 2: exploded drawing of single-phase electric pumps type ENM 25,
ENM 25S, ENM 30, ENM 35, ENM 40, ENM 50, ALM 25, ALM 30, ALM
40, ALM 50, EEM 25, EEM 30, EEM 35, EEM 40 and three-phase electric
pumps type ENT 25, ENT 25S, ENT 30, ENT 35, ENT 40, ENT 50, ALT
- Fig. 3A:
- Fig. 4
CC 12/20, ECC 24/20, AL 12/20, AL 24/20 have the motor part as shown
ECC 24/25, ECC 24/40, AL 12/25, AL 24/25, AL 24/40 have the motor
part as shown in Fig. 3 and the pump part as shown in Fig. 2.
- Fig. 9 replaces the parts ref. 18, 19, 20 of Figs. 1 and 2 in the partly
completed machinery of series EEMQ, ENMQ, ALMQ, ENTQ and ALTQ.
LeqA
TYPE
(dB)
69
ECC 24/25
77
ECC 24/40
71
ALM 20 L, ALT 20 L
83
ALM 20, ALT 20
74
ALM 25, ALT 25
81
ALM 30, ALT 30
81
ALM 40, ALT 40
77
ALM 50, ALT 50
78
AL 12/20
91
AL 24/20
91
AL 12/25
75
AL 24/25
76
AL 24/40
74
Tab. A
38
Fig. 3B: the various systems adopted for fixing
Hmax
1 m
5 m
10 m
(bar)
55
45
30
2.2
140
108
70
1.7
8
0.4
1.8
32
27
21
43
28
8
1.0
89
80
70
4.0
1.6
137
112
76
205
176
140
2.6
25
17
7
1.2
1.3
25
17
7
55
36
9
1.3
55
38
16
1.5
157
120
73
1.6
LeqA
(dB)
75
80
60
77
71
83
77
82
79.7
81.8
75.8
80.8
72.1

Publicité