Appendix / Anhang / Annexe
7.3.2.
gwt_5610.gsd
;=======================================================================
;GSD-Datei für das Profibus-Interface von PR1721/xx ab Firmware 3.12
;Stand 11.05.2004 - GLOBAL Weighing Technologies
;=======================================================================
;
#Profibus_DP
Vendor_Name
Model_Name
Revision
GSD_Revision
Ident_Number
Protocol_Ident
Station_Type
FMS_supp
Hardware_Release = "1.0"
Software_Release = "3.12"
Slave_Family = 0
Max_Diag_Data_Len=6
;
9.6_supp
= 1
19.2_supp
= 1
93.75_supp = 1
187.5_supp = 1
500_supp
= 1
1.5M_supp
= 1
3M_supp
= 1
6M_supp
= 1
12M_supp
= 1
;
MaxTsdr_9.6
= 60
raten
MaxTsdr_19.2
= 60
MaxTsdr_93.75 = 60
MaxTsdr_187.5 = 60
MaxTsdr_500
= 100
MaxTsdr_1.5M
= 150
MaxTsdr_3M
= 250
MaxTsdr_6M
= 450
MaxTsdr_12M
= 800
;
Redundancy = 0
Repeater_Ctrl_Sig
Implementation_Type = "SPC3"
24V_Pins
Freeze_Mode_supp
Sync_Mode_supp
Auto_Baud_supp
Set_Slave_Add_supp = 0
User_Prm_Data_Len
Min_Slave_Intervall = 50
Modular_Station = 1
Max_Module = 4
Max_Output_Len = 64
Max_Input_Len = 64
Max_Data_Len = 128
20
= "GLOBAL Weighing Technologies"
= "PR1721/xx Profibus Interface"
= "Version 1.3"
= 1
= 0x5610
= 0
;Nur DP-Gerät
= 0
;Kompakt Station
= 0
;unterstützte Baudraten
;max. Antwortzeiten bei den unterschiedlichen Baud-
;keine redundante Übertragung
= 2
; TTL
= 0
;keine 24V für den Anschluß eines Wartungsgerätes
= 1
;Freeze Modus wird unterstützt
= 1
;Sync Modus wird unterstützt
= 1
= 0
; 50x100uS->5ms. min. Slave intervall
;FMS wird nicht unterstützt
Fieldbus Interface
Sartorius