Troubles
1. Unit does not start
when pressing POWER
button.
2. Room is not cool
enough
3. Noisy operation
4. E0 Code
5. E2 /E4 Code
Note: illustrations in this manual are for information purposes only. Your air
conditioner may be different.

Troubleshooting

Possible Causes
- Water full indicator lamp blinks,
and water tank is full.
- Room temperature is higher than
the
set
temperature.
heating mode)
- Room temperature is lower than
the
set
temperature.
mode)
- The doors or windows are not
closed.
- There are heat sources inside the
room.
-
Exhaust
air
connected or blocked.
- Temperature setting is too high.
- Air inlet is blocked.
- The ground is not level or not flat
enough
- The sound comes from the
flowing of the refrigerant inside the
air conditioner
Room temperature sensor failed
Water tank full
Drain the water out of the
water tank.
Reset the temperature
(Electric
Reset the temperature
(Cooling
Make sure all the windows
and doors are closed.
Remove the heat sources if
possible
hose
is
not
Connect or clean the exhaust
air hose.
Reset the temperature
Clean the air inlet.
Place the unit on a flat, level
ground if possible
It is normal.
Replace room temperature
sensor (the unit can also
work without replacement.)
Please empty the water tank.