Télécharger Imprimer la page

Troubleshooting; Specifications - Uberhaus PC08-AMDII Guide De L'utilisateur

Climatiseur portatif 4 en 1

Publicité

Les langues disponibles

Les langues disponibles

Outdoor exhaust through window kit
(Optional function)
When using the window kit, please install A and B on the window with
screws, then install D into A (see picture). When the window kit is not used,
please take out D, and install C into A.
Before installing the window kit, please disconnect C and A.
Conversion from cooling to heating mode
To convert unit from cooling to heating mode, please change the exhaust pipe as
follows:
1.Remove the outlet grille (fig.1) and replace with the exhaust pipe assembly (fig.2).
Insert exhaust pipe as indicated (Fig.3).
13

TROUBLESHOOTING

Problem
Cause
E1
Electrical short on both temperature
sensor and PCB
E2
Electrical short of temperature sensor
copper tube and PCB wiring
E3
Leaking refrigerant from copper tube
E4
Indicates water tank is full or drainage
plug is not positioned properly

SPECIFICATIONS

Model No.
Power Source
Cooling Capacity
Heating Capacity
Refrigerant
Dimensions (W x H x D)
(30 x 63 x 48 cm)
(CE) N 842/2006:
R410A is a fluorinated greenhouse gas covered by
the Kyoto Protocol.
Its total global warming potential (GWP) is 1975.
Please discard or recycle your product and its packaging
according to your municipal bylaws.
Solution
Contact Customer Service for
repair
Contact Customer Service for
repair
Contact Customer Service for
repair
Pull out the rubber stopper located
at the bottom of the unit, to drain
the water. Replace plug correctly
and start unit.
PC08-AMDⅡ
PC10-AMD
120V~ 60Hz
8000 BTU/Hr
10,000 BTU/Hr
8000 BTU/Hr
10,000 BTU/Hr
R410A
12" x 25" x 19"
12" x 31" x 20"
(30 x 77.8 x 50.5 cm)
14

Publicité

loading

Ce manuel est également adapté pour:

02435000Pc10-amd02435001