Problem: Backwash/rinse cycle cannot be started manually.
Possible causes
Incorrect contact connected to
the pressure switch.
Problem: Valve is in the FILTER position, however water is
flowing to the sewage (inspection glass).
Possible causes
Contamination through
small parts or sand.
Valve seal loose or worn.
Cam disc is not set correctly.
Valve cover with actuating
drive was mounted on the
valve twisted by 180°.
Problem: Pool loses considerable water over time.
Possible causes
Unfavourable installation
conditions.
Please be aware that unintentional drops in the water level
can cause overlying roll-up covers to break. If necessary,
these should open automatically.
04|2019
Faults/troubleshooting
Solution
Reconnect the pressure
switch; use contacts 2 and
3. (Looking at the
pressure switch with the
contacts underneath,
these are the middle and
left contacts.)
Solution
Remove the valve lid and
find the cause of the
overload. Clean the valve
if necessary.
Remove the complete
upper part and send it to
the manufacturer.
Undo the screws, turn the
whole unit 180°, tighten
the screws. The angular
cams of the valve and
valve cover must match.
Solution
Check the installation
situation. If necessary,
install a special SPECK
non-return-valve
(240.9102.063).