STANDARD POWER CONNECTION
Connect the 2 electrical wires to the 2-point
terminal block, as shown below:
Observe the polarity of the wires
to avoid damaging the terminal.
The guarantee does not cover
any damage resulting from improper
use.
Check that the connectors on
the power cable are compatible
with your electrical system.
Follow the steps below to connect the terminal
to the network and power supply in the stan-
dard power supply configuration.
Thread the cable through the grommet.
➊
Do not use damaged power cords or plugs.
Do not twist or damage the power cable.
Prepare the wires in the cable and screw
➋
them onto the 2-point terminal block, obser-
ving the polarities shown above.
Install the 2-point terminal block in the
➌
matching baseplate. Tighten the two hol-
ding screws fitted to the ends of the terminal
block.
The terminal must be supplied with
a voltage of between 12 and 24 VDC.
10
PoE CONNECTION
Follow the steps below to connect the
terminal to the network and power supply in
the PoE power supply configuration.
Thread the cable through the grommet.
➊
Prepare the wires of the cable and screw
➋
them into the 9-point terminal block,
observing the color codes shown below.
Ground shielding
➊
Brown wire
➋
White/brown wire
➌
Green wire
➍
White/blue wire
➎
Plug the end of the cable into your PoE
➌
injector's Power+Data ("PD") port. Install
the 9-point terminal block in the matching
baseplate. Tighten the two holding screws
fitted to the ends of the terminal block.
Blue wire
➏
White/green wire
➐
Orange wire
➑
White/orange wire
➒