7 - FURTHER DETAILS
FUNCTIONS SELECTION
By operating on the jumpers present on the central control panel it
is possible to personalize the automation.
The table describes the working and the effect that the action on
each single jumper has on the central control panel.
N. B.: DISCONNECT THE POWER SUPPLY EACH TIME THAT
YOU OPERATE THE JUMPER!!!
POS.1: The transmitter works in IMPULSE MODE. The memorised key runs these functions:
OPEN...STOP...CLOSE...STOP.
THE SECOND CHANNEL memorised BY THE TRANSMITTER manages the PEDESTRIAN mode. (In
this mode the transmitter cannot carry out either the deadman function or the normal working function).
POS.2: The OPEN/CLOSE FUNCTION, manages the automation acting on the 2 transmitter keys. The
first commands the gate to open, the second to close. J1 in position 2 has another possibility of personali-
sing the central computer acting on jumper 2.
POS.1: Determines the NORMAL WORKING of the wall keys and the transmitter. By pressing the
open key the gate opens completely, pressing the key a second time blocks the gate. If it is necessary
to stop the movement it is necessary to press the key relative to the other direction, in this case the
close key. To close re-press the close key. The same applies to open the gate.
-In this J2 configuration the intervention of the photoelectric cells during closure blocks the
gate and inverts the movement.
POS.2: Determines the PERSON PRESENT function both with the keys on the wall and the transmitter
(if jumper 1 = POS.2). The automation begins to open or close for the precision time of the relative
transmitter button or the key.
-In this J2 configuration the intervention of the photoelectric cells stops the movement until the
obstacle has been removed. The movement will re-commence, either opening or closing as selected.
OPEN: The central computer allows FIXED CODE transmitter setting.
CLOSED: The central computer allows VARIABLE CODE transmitter setting. The closure of the jumper
DECODE gives another possibility of personalisation by acting on the jumper type VARIABLE CODE
ROLLING CODE.
IN ORDER TO PASS FROM FIXED CODE TO VARIABLE AND VICE VERSA IT IS NECESSARY TO
RESET THE CONTROL PANEL!
Condominium function:
The unit is provided with a deactivated master function.
The master function is activated and deactivated by using jumper J4.
J4 OPEN = CONDOMINIUM FUNCTION DEACTIVATED
J4 CLOSED = CONDOMINIUM FUNCTION ACTIVATED
To activate the master function, switch the unit first on and then
CONDOMINIUM FUNCTION:
The opening mechanism starts with an impulse command when the gate is closed. Any other impulse
command is ignored. Once completely opened, the reclosure is commanded only by time. If this is not
set, the gate remains open without possibility of closing again.
For this reason a preset reclosing time of 30 seconds has been considered.
The photocell is engaged to reload the entire reclosing time when the gate is open. If the photocell re-
mains interrupted the gate does not restart.
During reclosure, an impulse command stops the unit and makes the automation totally reopen.
OPEN/CLOSE function or LIMIT SWITCH :
J5 jumper configuration for limit switch or button selection
J5 OPEN: button selection
J5 CLOSE: limit switch selection
20
20
SELECTION
MODE
J1
J2
J3
J4
J5
MEMORY
A.R
FUSE
W.T
6,3 A
CD.
MIN
MAX
1
2
3
4
5
6
7
8
9
10
11
12
13
14 15
N.O.
N.O.
N.C.
N.C.
O
LMO
C
LMC
COM
COM
KEY:
C = closing button
O = opening button
LMC = closing limit switch
LMO = opening limit switch
J1
J2
J3
J4
J5
J1
POS.1 POS.2
J2
POS.1 POS.2
J3
J4
J5