Control Terminals - Lenze E94 SHE Single Drive HighLine Série Instructions De Montage

Masquer les pouces Voir aussi pour E94 SHE Single Drive HighLine Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

6.4

Control terminals

System bus CAN on board
Terminal X1
9400SSP000X1
24 V supply
Terminal X2
9400SSP000X2
Terminal data
Flexible
With wire end
ferrule
Analog inputs, analog outputs
Terminal X3
SSP94000X3
Terminal data
Flexible
With wire end
ferrule
EDK94SH104 DE/EN/FR/ES/IT 8.0
Labelling
Description
Pin 2
CAN−LOW
Pin 3
CAN−GND
Pin 7
CAN−HIGH
(Housing)
CAN−Shield
Labelling
Description
GE
GND external supply
24E
24 V external supply via a safely separated power supply
unit (SELV/PELV) (only required for mains−independent supply of the
control electronics)
SB
State bus in/out (reference GE)
Conductor cross−section
2
[mm
]
0.2 ... 2.5
Labelling
Description
GA
GND analog signals
AO1
Analog output 1
AO2
Analog output 2
A1+
Analog input 1 +
A1−
Analog input 1 −
A1−
Analog input 1 −
A1R
Terminating resistor for ±20mA
A2+
Analog input 2 +
A2−
Analog input 2 −
"
Shield connection: Fix the shield with EMC wire clamp.
Conductor cross−section
2
[mm
]
0.2 ... 2.5
l
Wiring the device
Control terminals
Tightening torque
[AWG]
[Nm]
24 ... 12
Spring terminal
Tightening torque
[AWG]
[Nm]
24 ... 12
Spring terminal
6
[lb−in]
[lb−in]
73

Publicité

Table des Matières
loading

Table des Matières